Inspection
Inspection Details
Equipment ID
13736
13736
Inspection Date
11/5/2020
11/5/2020
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Kurt Zimmerman
Kurt Zimmerman
Mechanic Name
Matthew Fernandez
Matthew Fernandez
Relief Valve Pressure
Slide
NA
NA
Governor Rope Pull
NA
NA
Door Closing Force
NA
NA
External ID
02273c07-b75e-496a-bd83-a7a3b88a5f3a
02273c07-b75e-496a-bd83-a7a3b88a5f3a
Location
The Ellsworth
4405 W PINE BLVD, SAINT LOUIS, MO
Phone: (314) 535-6466
4405 W PINE BLVD, SAINT LOUIS, MO
Phone: (314) 535-6466
Owner
Attn: Anshul Sathyan
Revival STL
PO Box 46721, SAINT LOUIS, MO 63146
Phone: (314) 852-6755
Email: anshul@revivalstl.com
Revival STL
PO Box 46721, SAINT LOUIS, MO 63146
Phone: (314) 852-6755
Email: anshul@revivalstl.com
Billing
Attn: The Ellsworth
The Ellsworth
4405 W PINE BLVD, SAINT LOUIS, MO 63108
Phone: (314) 852-6755
Email: anshul@revivalstl.com
The Ellsworth
4405 W PINE BLVD, SAINT LOUIS, MO 63108
Phone: (314) 852-6755
Email: anshul@revivalstl.com
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (I) - Pits | (I)1 | The elevator pit shall be kept dry. | 6/3/2019 | ||
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | Newly installed plumbing vent is vented into machine room. Either remove pipe or move machine fence to get pipe out of machine room. | 11/18/2020 | ||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.2.1 General Maintenance Requirements Documentation | Provide written maintenance control program on site for each elevator. | 11/18/2020 | ||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | Fire extinguisher in the machine room is outdated. Update fire extinguisher | 12/15/2021 | ||
| MO Minimum : Elevators | (I) - Pits | (I)1 | Pit shall be clean of debris. | 12/15/2021 | ||
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | x | White PVC vent pipe shall be removed from machine room, it is in front of the main line disconnect, this is the second time this has been written up. | 9/1/2023 | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) | x | Emergency light shall be made operational | 9/1/2023 | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.2.1 General Maintenance Requirements Documentation | Provide maintenance control programs on site for each elevator | 9/8/2023 | ||
| MO Minimum : Elevators | (I) - Pits | (I)1 | Pits shall be kept clean of debris | 9/8/2023 | ||
| MO Minimum : Elevators | (I) - Pits | (I)1 | Pit shall be kept clean of water and debris | 9/8/2023 | ||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.4.9 Cleaning of Top of Cars | Car top needs cleaned | |||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6 General Maintenance Methods | Machine is covered in oil and needs cleaned | |||
| MO Minimum : Elevators | (I) - Pits | (I)1 | Pit needs cleaned | |||
| MO Minimum : Elevators | (L) - Wire Ropes-Hoisting, Governor and Tiller | (L)12 (Re- Inspection) | x | Two of the hoist ropes are crossed and one shackle has a hoist rope incorrectly seated. | ||
| MO Minimum : Elevators | (L) - Wire Ropes-Hoisting, Governor and Tiller | (L)12 (Re- Inspection) | x | Runby is 2 - Hoist ropes need shortened. | ||
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)8 Car Lighting | Car lighting is hanging and needs properly fastened | |||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6 General Maintenance Methods | Repair Broken Flex to electrical box on crosshead | |||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6 General Maintenance Methods | Remove unused hanging and broken electrical cable from hoistway (can be seen from pit) | |||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6 General Maintenance Methods | Manual Gate is missing a handle and creates a pinch hazard |