Inspection
Inspection Details
Equipment ID
1452
1452
Inspection Date
11/18/2020
11/18/2020
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Steven Salabay
Steven Salabay
Mechanic Name
Richard King
Richard King
Relief Valve Pressure
Slide
Governor Rope Pull
Door Closing Force
External ID
d79c3a56-18ce-4158-b289-b27b760e0d31
d79c3a56-18ce-4158-b289-b27b760e0d31
Location
Macy's- West Store / #652
2 W COUNTY CTR # 120012, SAINT LOUIS, MO
Phone: (314) 966-0017
2 W COUNTY CTR # 120012, SAINT LOUIS, MO
Phone: (314) 966-0017
Owner
Attn: Cathie Sherman
MACY'S MSOC VERTICAL COMPLIANCE
237 Woodbridge Center Dr, 3rd Flr, Woodbridge, NJ 07095
Phone: (732) 734-3438
Email: Cathie.Sherman@macys.com
MACY'S MSOC VERTICAL COMPLIANCE
237 Woodbridge Center Dr, 3rd Flr, Woodbridge, NJ 07095
Phone: (732) 734-3438
Email: Cathie.Sherman@macys.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | REpair skirt lighting | 6/15/2020 |
| A17.1-1996 : Escalators | 7.5 - Lighting | 806.2 | No | No | Repair skirt light top of unit | 6/15/2020 |
| A17.1-1996 : Escalators | 7.15 - Balustrades | 802.3 | No | No | Replace missing Balustrate trim | 6/15/2020 |
| A17.1-1996 : Escalators | 7.17 - Step/skirt clearances, panels, and performance index | 802.3e | No | No | Provide copy of missing step index test results to complete inspection | 6/15/2020 |
| A17.1-1996 : Escalators | 8.1 - Machinery space access, lighting, receptacle, and condition | 806 | No | No | Clean down trust | 6/15/2020 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.1.4 Maintenance Records | No | No | Need maintenance control program on site posted on controller | 10/3/2025 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.8.1 Escalator Handrails | No | No | right handrail torn needs replacing | 10/3/2025 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.8.13 Escalator Cleaning | No | No | Unit needs to be cleaned down | 10/3/2025 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.11.4.2.13 Escalator Handrail Safety Systems | No | No | left handrail torn needs replacing | 10/3/2025 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.8.13 Escalator Cleaning | No | No | Clean down truss | 10/3/2025 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.1.4 Maintenance Records | No | No | Provide a complete maintenance control program to include wiring diagrams | 10/3/2025 |
| Missouri Minimum : Escalators | CSR 40-5.100 State Operating Certificate | 5.100(2) display of certificate | No | No | Post current state certificate in machine room | 10/3/2025 |