Inspection
Inspection Details
Equipment ID
14589
14589
Inspection Date
6/13/2018
6/13/2018
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Gary Beadle
Gary Beadle
Mechanic Name
David Howerton
David Howerton
Relief Valve Pressure
430
430
Slide
Governor Rope Pull
Door Closing Force
21
21
External ID
a894f422-c1ff-474b-b1d2-7cf1167bf4f6
a894f422-c1ff-474b-b1d2-7cf1167bf4f6
Location
Mesnier Elementary School
6930 WEBER RD, AFFTON, MO
6930 WEBER RD, AFFTON, MO
Owner
Affton School District
8701 MACKENZIE RD, AFFTON, MO 63123-3436
8701 MACKENZIE RD, AFFTON, MO 63123-3436
Billing
Attn: Affton School District
8701 MACKENZIE RD, AFFTON, MO 63123-3436
8701 MACKENZIE RD, AFFTON, MO 63123-3436
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| A17.1-1996 : Elevators | 1.5 - Car lighting and receptacles | 204.7 | No | No | Provide existing emergency lights to work | 7/13/2020 |
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | In cab alarm bell shall work. | 9/5/2018 |
| A17.1-1996 : Elevators | 2.7 - Fire Extinguisher | 1001.2(b)(7) | No | No | The fire extinguisher in the elevator machine room is expired and shall be replaced or serviced. | 7/13/2020 |
| A17.1-1996 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | No | No | A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022) | 10/19/2023 |
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | The emergency phone dials and then hangs up. The in car emergency telephone shall operate per code. | 8/16/2023 |
| A17.1-1996 : Elevators | 11 CSR 40-5.090 Inspection and Testing | 8.6.5.16.5 Over Speed Valve Testing | No | No | The overspeed valve was last tested in 2017. It shall be tested with the rated load on or before the next annual inspection. | 8/16/2023 |
| A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | There is no state operating certificate in the machine room. | 10/19/2023 |
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 306.11 (Hydro) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency phone does not work. | 11/4/2024 |
| A17.1-1996 : Elevators | 1.17 - Standby power operation | 211.2 | Yes | No | Battery lowering does not work. | 11/4/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.7 Signs and Data Plates | No | No | Overspeed Valve tag is not updated. | 8/22/2024 |