Inspection
Inspection Details
Equipment ID
23677
23677
Inspection Date
1/10/2018
1/10/2018
Inspection Type
New Installation
New Installation
Inspector Name
Rick Buttice
Rick Buttice
Mechanic Name
Shane Warth
Shane Warth
Relief Valve Pressure
Slide
4"
4"
Governor Rope Pull
60/210
60/210
Door Closing Force
20F/22R
20F/22R
External ID
42e13a35-cfaa-4267-b5e4-04b25a95ec43
42e13a35-cfaa-4267-b5e4-04b25a95ec43
Location
Vanguard Clayton
8500 MARYLAND AVE, CLAYTON, MO
8500 MARYLAND AVE, CLAYTON, MO
Owner
Vanguard Clayton Apartments LP
135 N MERAMEC AVE, SAINT LOUIS, MO 63105-3751
135 N MERAMEC AVE, SAINT LOUIS, MO 63105-3751
Billing
Attn: Vanguard Clayton Apartments LP
135 N MERAMEC AVE, SAINT LOUIS, MO 63105-3751
135 N MERAMEC AVE, SAINT LOUIS, MO 63105-3751
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.10 - Hoistway construction | 2.1 | Yes | No | Seal all penetrations in the hoistway. | 4/27/2018 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 2.27.2-2.27.8 | Yes | No | Complete installation and testing of components of fire service. | 4/27/2018 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.17 - Drive machine brake | 8.11.2.1.2(o) | Yes | No | Repair manual rescue brake release. | 3/19/2021 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Check govenor rope pull through and pull out force. Re-inspection required | 10/19/2023 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Check governor switch and jaws tripping speed. Re-inspection required | 10/19/2023 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Test drive machine brake with 125% of rated load. Re-inspection required | 10/19/2023 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Test car safeties at rated speed with rated load. Re-inspection required | 10/19/2023 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Test unintended car movement with 125% of rated load. Re-inspection required | 10/19/2023 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Clean debris from elevator pit. | 10/19/2023 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.5 - Housekeeping | 8.6.4.9 Cleaning of Car Tops | No | No | Clean dirt from elevator car top | 10/19/2023 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.6 - Car emergency signal | 2.27.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Two-Communication inoperable and shall be repaired, or replaced. Reinspection required. | 12/20/2024 |