Inspection
Inspection Details
Equipment ID
23902
23902
Inspection Date
12/11/2020
12/11/2020
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Steven Salabay
Steven Salabay
Mechanic Name
Richard King
Richard King
Relief Valve Pressure
Slide
NA
NA
Governor Rope Pull
NA/NA
NA/NA
Door Closing Force
18
18
External ID
f125e7bd-ed98-4ad0-aa8f-9be502a13f98
f125e7bd-ed98-4ad0-aa8f-9be502a13f98
Location
Fairfield Inn/ Residence
11920 WESTLINE INDUSTRIAL DR, SAINT LOUIS, MO
11920 WESTLINE INDUSTRIAL DR, SAINT LOUIS, MO
Owner
Attn: Fairfield Inn
Midas Westport II, LLC
1804 BORMAN CIRCLE DR, SAINT LOUIS, MO 63146
Phone: (314) 764-4262
Email: kprainito@midashospitality.com
Midas Westport II, LLC
1804 BORMAN CIRCLE DR, SAINT LOUIS, MO 63146
Phone: (314) 764-4262
Email: kprainito@midashospitality.com
Billing
Same as Owner
Violations
Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
---|---|---|---|---|---|---|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.6 - Car emergency signal | 3.27 (Hydro) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | x | Emergency phone shall work. | 2/19/2019 | |
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 8.6.4.7 Cleaning of Pits | Pit shall be kept clean and dry. | 3/25/2019 | ||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 2.2.2 Design and Construction of Pits | Remove water from pit | 11/1/2019 | ||
A17.1-2016 : Elevators | 2.40 - Maintenance Records | 8.6.1.2.1(a) | Need maintenance control program on site posted on controller on or by next test | 12/21/2020 | ||
A17.1-2016 : Elevators | 2.40 - Maintenance Records | 8.6.1.2.1(a) | Need testing procedures in the MCP on or before 1/1/22 | 12/20/2021 | ||
A17.1-2016 : Elevators | 5.6 - Governor-rope tension devices | 8.11.2.1.5(g) | Replace rusting conduit to governor tail sheave switch 620.21 | 1/5/2023 | ||
A17.1-2016 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 8.11.2.1.5(a) | Channel pit floor to sump pump in drain standing water. 2.2.2.3 | 1/5/2023 | ||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.20 - Governor rope | 8.11.2.1.3(z) | x | Shorten Governor rope 2.18.6.4 | 11/21/2022 | |
A17.1-2016 : Elevators | 3.6 - Final and emergency terminal stopping devices | 8.11.2.1.3(h) | x | x | Repair bottom final limits switch operations 2.25.3.2 | 11/21/2022 |
A17.1-2016 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 8.11.3.1.5(a) | Channel Pit Floor to sump pump to drain Standing water in pit 2.2.2.3 | 1/5/2023 | ||
A17.1-2016 : Elevators | 3.23 - Suspension Means | 8.6.3.2 (Re-Inspection) | x | Hoisting belts have red rouge all over needs to be replaced | 10/19/2023 | |
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.23 - Suspension rope | 8.11.2.1.3(cc)(1) Wire ropes shall be replaced | x | x | reinspectin for rouge on hoisting belts, no engineer letter supplied to me, 15 days to either receive letter from engineer stating belts are ok or the belts to be replaced or a rd tag unit place out of service. | 1/15/2024 |
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.3 - Lighting and receptacles | 2.7.5.1 Lighting | Repair machine space hoistway-top lighting | |||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.13 - Governor,overspeed switch and seal | 2.17.15 | x | Repair governor tail sheave switch | 11/12/2024 | |
MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | x | Complete annual CAT 1 test | 11/12/2024 | |
MO Minimum : Elevators | (S) - Fire Service | 8.6.11.1 Monthly Test and Log | x | Tested fire service failed |