Inspection
Inspection Details
Equipment ID
17626
17626
Inspection Date
5/15/2018
5/15/2018
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Edward Balsat
Edward Balsat
Mechanic Name
Kenneth Gustavson
Kenneth Gustavson
Relief Valve Pressure
420
420
Slide
Governor Rope Pull
Door Closing Force
20
20
External ID
6fea1701-affe-4c27-a20c-84e5a1fe4cbe
6fea1701-affe-4c27-a20c-84e5a1fe4cbe
Location
Field School Lofts
4466 OLIVE ST, SAINT LOUIS, MO
4466 OLIVE ST, SAINT LOUIS, MO
Owner
Field Landlord L.P.
4500 OLIVE ST APT K, SAINT LOUIS, MO 63108-1841
4500 OLIVE ST APT K, SAINT LOUIS, MO 63108-1841
Billing
Attn: Field Landlord L.P.
4500 OLIVE ST APT K, SAINT LOUIS, MO 63108-1841
4500 OLIVE ST APT K, SAINT LOUIS, MO 63108-1841
Violations
Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
---|---|---|---|---|---|---|
A17.1-1996 : Elevators | 1.18 - Restricted opening of car or hoistway doors | 1001.2(a)(18) | x | Make door restrictor operational. | 10/18/2018 | |
A17.1-1996 : Elevators | 3.3 - Top-of-car operating device | 1001.2(c)(3) | Make car top run station operational. - Reinspection Required | 10/25/2018 | ||
A17.1-1996 : Elevators | 1.6 - Car emergency signal | 1001.2(a)(6) (Red Tag) | x | In cab emergency telephone shall work. | 10/18/2018 | |
A17.1-1996 : Elevators | 1.6 - Car emergency signal | 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | x | Existing cab emergency telephone shall work with 24/7 support. | 10/24/2018 | |
A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | Display current state operating certificate. | 10/25/2018 | ||
A17.1-1996 : Elevators | 1.6 - Car emergency signal | 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | x | Emergency light inoperative. | 11/24/2020 | |
A17.1-1996 : Elevators | 2.7 - Fire Extinguisher | 1001.2(b)(7) | Service fire extinguisher. | 11/1/2022 | ||
A17.1-1996 : Elevators | 1.6 - Car emergency signal | 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | x | Emergency light does not work. | 6/16/2021 | |
A17.1-2016 : Elevators | 2.7 - Fire Extinguisher | 8.6.1.6.5 | Fire extinguisher is expired | 11/1/2022 | ||
A17.1-2016 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | A copy of the state operating certificate shall be displayed in the elevator machine room | 11/1/2022 | ||
A17.1-2016 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 2.2.5 | Pit light bulbs shall be guarded | 11/1/2022 | ||
A17.1-2016 : Elevators | 2.8 - Pipes, wiring, and ducts | 2.8.2 | Smoke device in pit needs to be remounted on electrical box | 11/1/2022 |