Inspection
Inspection Details
Equipment ID
21377
21377
Inspection Date
12/3/2020
12/3/2020
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Edward Balsat
Edward Balsat
Mechanic Name
David Howerton
David Howerton
Relief Valve Pressure
Slide
NA
NA
Governor Rope Pull
NA
NA
Door Closing Force
NA
NA
External ID
fc213345-959d-46a9-8aa3-6119b0d39d3d
fc213345-959d-46a9-8aa3-6119b0d39d3d
Location
Chemline Inc
5151 NATURAL BRIDGE AVE, SAINT LOUIS, MO
Phone: (314) 664-2230
5151 NATURAL BRIDGE AVE, SAINT LOUIS, MO
Phone: (314) 664-2230
Owner
Attn: Matt Shampine
Chemline Inc
5151 Natural Bridge Ave, St. Louis, MO 63115
Phone: (314) 664-2230 Ext: 133
Alt Phone: (314) 773-9238
Email: matt.shampine@chemline.net
Chemline Inc
5151 Natural Bridge Ave, St. Louis, MO 63115
Phone: (314) 664-2230 Ext: 133
Alt Phone: (314) 773-9238
Email: matt.shampine@chemline.net
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | Replace electrical conduit on side of car | 7/25/2018 |
| conversion | conversion | n/a | No | No | Cover junction box on car top | 7/25/2018 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | Fire extinguisher needs to be serviced. | 12/11/2018 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | No | No | Provide a current tested fire extinguisher in the elevator machine room. | 3/8/2022 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | The machine room door shall be self-closing and self-locking. | 3/8/2022 |
| MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | No | No | A permanent lighting fixture shall be provided in all pits to provide illumination of not less then 5 ftc at the pit floor. | 3/8/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | No | No | Provide a code compliant MCP including onsite documents. | 3/8/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | No | No | A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. Evacuation procedures are missing. (This item is for notification purposes for future violation in 2022) | 3/7/2022 |
| MO Minimum : Elevators | (M) - Car Safeties and Speed Governors | (M)4 | Yes | Yes | The movement of the safety drum rope, starting from a fully retracted position, must not exceed 42 inches (it pulled out approximately 120 inches) before the safety shoes contact the rail. Elevator Red Tagged. | 10/10/2022 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Water and oil shall not be allowed to accumulate on the pit floors. Note: The pit floor is covered with several inches of water. | 3/14/2023 |
| MO Minimum : Elevators | (A) - Hoistways | (A)16 | No | No | All electrical wiring in the hoistway shall be enclosed in metal conduit, flexible conduit, metal raceway, or be in compliance with NFPA70. Note: There are bare wires running throughout the hoistway. | 3/14/2023 |
| MO Minimum : Elevators | (A) - Hoistways | (A)16 | No | No | The missing junction box covers in the hoistway shall be replaced. | 3/14/2023 |
| MO Minimum : Elevators | (A) - Hoistways | (A)12 | No | No | The penetrations in the hoistway shall be sealed with approved materials. | 3/14/2023 |
| MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | No | No | The fluorescent pit light shall be operational and permanently wired. Note: The fixture is currently attached to a cord which runs through a hole in the hoistway wall and is plugged into an extension cord. | 3/14/2023 |
| MO Minimum : Elevators | (C) - Car Enclosure: Freight | (C)5 | No | No | Properly secure cab lights to ceiling. | 10/14/2025 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 10/17/2025 |