Inspection
Inspection Details
Equipment ID
25087
25087
Inspection Date
11/25/2020
11/25/2020
Inspection Type
Temporary Certificate Inspection
Temporary Certificate Inspection
Inspector Name
Daniel Letcher
Daniel Letcher
Mechanic Name
Matthew Secrest
Matthew Secrest
Relief Valve Pressure
Slide
7"
7"
Governor Rope Pull
n/a
n/a
Door Closing Force
28
28
External ID
6ec25d75-65c4-4bcd-a0bf-33ce5b326098
6ec25d75-65c4-4bcd-a0bf-33ce5b326098
Location
American Electric
302 North 3rd Street, St Joseph, MO
Phone: (913) 642-6000
302 North 3rd Street, St Joseph, MO
Phone: (913) 642-6000
Owner
Attn: Wes Grammer
302 North 3rd Street, LLC
P.O Box 22876, Kansas City, MO 64113
Phone: (913) 642-6000
302 North 3rd Street, LLC
P.O Box 22876, Kansas City, MO 64113
Phone: (913) 642-6000
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| A17.1-2016 : Elevators | 1.4 - Sills and car floor | 8.10.2.2.1(d) | No | No | car floor not installed | 12/7/2021 |
| A17.1-2016 : Elevators | 1.17 - Standby power operation | 2.27.2 | Yes | No | Emg standby power nt tested | 12/7/2021 |
| A17.1-2016 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 2.27.3 | Yes | Yes | fire int. devices not tested | 12/7/2021 |
| A17.1-2016 : Elevators | 1.15 - sign and operating device symbols | 8.10.2.2.1(o) | No | No | in case of fire signage not displayed | 12/7/2021 |
| A17.1-2016 : Elevators | 3.11 - Hoistway smoke control | 2.1.4 | No | No | smoke damper not tested | 12/7/2021 |
| A17.1-2016 : Elevators | 2.13 - Governor, Overspeed Switch, and Seal | 2.18.6 | Yes | No | gov pull thru not tested | 12/7/2021 |
| A17.1-2016 : Elevators | 5.8 - Car safeties and guiding members - including roped-hydraulic elevators installed under A17.1b-1989 and later editions | 8.10.2.2.5(j) | Yes | Yes | didnt test car safties | 12/7/2021 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current State certificate in machine room | 2/22/2022 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current state certificate in machine room | 2/6/2023 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.5 - Car lighting and receptacles | 8.6.4.15 Emergency Lighting | Yes | No | Emergency light did not come on, repair emergency light | 3/26/2026 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.12 - Pipes, wiring, and ducts | 2.8 | No | No | Instal cover on 4x4 junction box top of hoistway below the disconnect and at bottom of the hoistway next to the divider beam | 3/26/2026 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.17 - Drive machine brake | 8.11.2.3.4 | Yes | Yes | Failed the 125% brake test, adjust or replace brake depending on the type of brake. Unit is red tagged until repair has been reinspected | 3/26/2026 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.5 - Car lighting and receptacles | 8.6.4.15 Emergency Lighting | Yes | No | Emergency light did no come on | |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.12 - Pipes, wiring, and ducts | 2.8 | No | No | install cover on 4x4 Junction box top of hoistway below the disconnect and at bottom of hoistway next to the divider beam |