Inspection
Inspection Details
Equipment ID
15157
15157
Inspection Date
12/22/2020
12/22/2020
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Michael Ledden
Michael Ledden
Mechanic Name
John Hambrough
John Hambrough
Relief Valve Pressure
Slide
NA
NA
Governor Rope Pull
NA
NA
Door Closing Force
28
28
External ID
556d25cc-b920-4cdd-9d96-6dd7dceb382d
556d25cc-b920-4cdd-9d96-6dd7dceb382d
Location
SoHo Towers
5340 DELMAR BLVD, SAINT LOUIS, MO
Phone: (314) 367-7646
5340 DELMAR BLVD, SAINT LOUIS, MO
Phone: (314) 367-7646
Owner
Attn: Helix
Helix Realty Inc
5340 DELMAR BLVD APT 104, SAINT LOUIS, MO 63112
Phone: (314) 367-7646
Email: helixrealty@gmail.com
Helix Realty Inc
5340 DELMAR BLVD APT 104, SAINT LOUIS, MO 63112
Phone: (314) 367-7646
Email: helixrealty@gmail.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | conversion - reinspect | Yes | No | Wind up car safety rope shall be made of a non-corrosive material. | 12/4/2018 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)8 | No | No | The hoist motor and motor generator sets shall have junction box covers in place. | 2/1/2021 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Ran into issues during testing. The following items shall be tested to complete the annual inspection and category 5 test: Testing of lights, alarm, and phone with 110v removed, Governor pull out/pull thru, governor electrical switch and jaw, slide, oil buffer test, 125 % weight test. | 1/18/2022 |
| MO Minimum : Elevators | (M) - Car Safeties and Speed Governors | (M)4 | Yes | Yes | The safety drum rope shall not pullout more than 36". Currently pulls out 55". Red Tag Issued | 8/3/2023 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Two-way communication device shall work with and without main power. | 8/3/2023 |
| MO Minimum : Elevators | (M) - Car Safeties and Speed Governors | (M)5 | Yes | Yes | SOS switch will not reset. Take corrective action as needed. | 8/3/2023 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | The pit needs to be cleaned. | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.7 Signs and Data Plates | No | No | The correct elevator number shall be displayed on the crosshead. | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.13 - Door systems | No | No | Adjust upthrust roller bearings for proper clearance to door hanger track. | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.7 Signs and Data Plates | No | No | Suspension means shall have proper data tag. | |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | There is no state operating certificate in the machine room. | |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | Machine room windows are broken and missing panes. | |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)8 | No | No | 4 x 4 electrical box in machine room needs to have wiring inside box and cover installed. | |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | Machine room door shall be self-closing, self-locking, and operable from the interior space without the use of a key. | |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)1 | No | No | Roof to machine room stairs are deteriorated, handrail has broken loose from concrete creating an unsafe condition. Repair/replace as needed to provide safe access. | |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)10 Car Floors | No | No | Cab floor to sill to hall floor shall be level and even. Currently, the cab and hall flooring are +1/2" above sill heights creating a tripping hazard. Repair/replace as needed. | |
| MO Minimum : Elevators | (M) - Car Safeties and Speed Governors | (M)4 | Yes | Yes | The safety drum rope shall not pullout more than 36". Currently pulls out 55". | 9/8/2023 |
| MO Minimum : Elevators | (M) - Car Safeties and Speed Governors | (M)5 | Yes | Yes | SOS switch will not reset. Take corrective action as needed. | 9/8/2023 |