Inspection
Inspection Details
Equipment ID
25330
25330
Inspection Date
12/23/2020
12/23/2020
Inspection Type
New Installation
New Installation
Inspector Name
Robert Kehm
Robert Kehm
Mechanic Name
Shane Warth
Shane Warth
Relief Valve Pressure
Slide
3"
3"
Governor Rope Pull
40/190
40/190
Door Closing Force
24
24
External ID
c7cfce85-5b21-42c8-959b-8949caf32654
c7cfce85-5b21-42c8-959b-8949caf32654
Location
Lofts at the Hupp
1815 Locust St, St Louis, MO
Phone: (000) 000-0000
1815 Locust St, St Louis, MO
Phone: (000) 000-0000
Owner
Attn: 1815 Locust LLC
1815 Locust LLC
7777 Bonhomme Ave Suite 2010, St Louis, MO 63105
Phone: (000) 000-0000
1815 Locust LLC
7777 Bonhomme Ave Suite 2010, St Louis, MO 63105
Phone: (000) 000-0000
Billing
Same as Owner
Violations
Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
---|---|---|---|---|---|---|
A17.1-2016 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 2.27.3 | x | x | Phase 1 & 2 fire service and all initiating devices shall be tested. | 6/30/2021 |
A17.1-2016 : Elevators | 4.8 - Hoistway enclosure | 8.10.2.2.4(h) | x | Screws protruding into the hoistway shall be removed. | 6/30/2021 | |
A17.1-2016 : Elevators | 4.8 - Hoistway enclosure | 8.10.2.2.4(h) | x | The door at the top of the hoistway shall be blocked up. | 6/30/2021 | |
A17.1-2016 : Elevators | 3.13 - Windows, projections, recesses, and setbacks | 2.1.6 | x | Beams in the back of the hoistway and concrete ledge in the pit shall be beveled to an angle not less than 75 degrees. | 6/30/2021 | |
A17.1-2016 : Elevators | 2.1 - Access to machine space | 2.7.3.4 | x | The machine room door shall be self-closing and self-locking. | 6/30/2021 | |
A17.1-2016 : Elevators | 1.6 - Car emergency signal | 2.27.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | x | Emergency phone is not working. Re-inspection required | 4/19/2022 | |
A17.1-2016 : Elevators | 1.6 - Car emergency signal | 2.27.1.1.6 Verification of Telephone Operability | Phone line monitor is not working correctly | 6/7/2022 | ||
A17.1-2016 : Elevators | 2.42 - Earthquake Inspection and Tests (Seismic Risk Zone 2 or Greater) | 8.4 | Counterweight derailment device is not working | 4/5/2022 | ||
A17.1-2016 : Elevators | 11.10 - Governor, Overspeed Switch | 2.18.7.2 | Govenor tail sheave switch is not working | 4/5/2022 | ||
A17.1-2016 : Elevators | 1.6 - Car emergency signal | 2.27.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | x | Phone not working correctly, repair as needed. | 6/8/2022 | |
A17.1-2016 : Elevators | 1.6 - Car emergency signal | 2.27.1.1.6 Verification of Telephone Operability | Phone line monitoring not working correctly, repair as needed. Reinspect required. | 4/5/2022 | ||
A17.1-2016 : Elevators | 1.6 - Car emergency signal | 2.27.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | x | Video monitoring is not working and shall be operational. (Phone is working) | 2/29/2024 | |
A17.1-2016 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 8.6.4.7 Cleaning of Pits | The pit shall be kept clean. Clean the pit. | |||
A17.1-2016 : Elevators | 1.6 - Car emergency signal | 8.6.4.15 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | x | Video monitoring does not work. |