Inspection
Inspection Details
Equipment ID
19864
19864
Inspection Date
1/18/2021
1/18/2021
Inspection Type
Reinspection
Reinspection
Inspector Name
Christopher "RED" Staton
Christopher "RED" Staton
Mechanic Name
Relief Valve Pressure
Slide
Governor Rope Pull
Door Closing Force
External ID
4b273009-0f7d-4e55-9cbb-9a0864714398
4b273009-0f7d-4e55-9cbb-9a0864714398
Location
JC Penney- Springfield
2825 S Glenstone Ave, Springfield, MO
Phone: (417) 883-4220
2825 S Glenstone Ave, Springfield, MO
Phone: (417) 883-4220
Owner
Attn: JC Penney #1188-2 Springfield
JC Penney #1188-2 Springfield
2825 S Glenstone Ave, Springfield, MO 65804
Phone: (000) 000-0000
JC Penney #1188-2 Springfield
2825 S Glenstone Ave, Springfield, MO 65804
Phone: (000) 000-0000
Billing
Attn: JCPenney
JCPenney
6501 Legacy Dr, Plano, TX 75024
Phone: (000) 000-0000
Email: jtyler15@jcp.com
JCPenney
6501 Legacy Dr, Plano, TX 75024
Phone: (000) 000-0000
Email: jtyler15@jcp.com
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | truss, upper & lower ends need clean down | 6/24/2019 |
| conversion | conversion | n/a | No | No | truss, upper & lower ends need clean down | 6/24/2019 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Certificate | No | No | no current certificate | 1/14/2022 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 7.5 - Lighting | 8.6.11.5(i) Demarcation Lighting (Re-Inspect) | Yes | No | 2019-2020: Step demarcation lights not working upper and lower. (2nd year violation) | 12/24/2020 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 8.1 - Machinery space access, lighting, receptacle, and condition | 8.11.4.2.1 (Re-Inspection) | No | No | 8.1.2: Escalator machine spaces(pits) lighting and receptacles will not be controlled by facility “lighting timers”. Replace missing lower pit bulb and cover. | 1/14/2022 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 8.1 - Machinery space access, lighting, receptacle, and condition | 8.6.8.13 | No | No | 8.1.2: Escalator machine spaces(pits) shall be kept clean and free from excessive debris. | 1/14/2022 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 8.1 - Machinery space access, lighting, receptacle, and condition | 8.6.8.13 | No | No | 2018 & 2020: 8.1.2 : truss, upper & lower ends need clean down. (Violation not corrected as of 8/2020) | 1/14/2022 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Certificate | No | No | 11 CSR 40-5.100(2) : Current State Operating Permit shall be displayed in the Equipment Room in a non-combustible frame. | 1/14/2022 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 8.1 - Machinery space access, lighting, receptacle, and condition | 8.11.4.2.1 (Re-Inspection) | No | No | 8.1.2: Escalator machine spaces(pits) lighting and receptacles will not be controlled by facility “lighting timers”. Replace missing lower pit bulb and cover. | 12/24/2020 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 8.1 - Machinery space access, lighting, receptacle, and condition | 8.6.8.13 | No | No | 8.1.2: Escalator machine spaces(pits) shall be kept clean and free from excessive debris. | 12/24/2020 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 8.1 - Machinery space access, lighting, receptacle, and condition | 8.6.8.13 | No | No | 2018 & 2020: 8.1.2 : truss, upper & lower ends need clean down. (Violation not corrected as of 8/2020) | 12/24/2020 |
| A17.1-2016 : Elevators | 8.13 - Handrail systems and safety devices | 6.1.3.4 (Hand Rails) (Re-Inspection) | No | No | /7.3.1(a) Handrails will be free of major cracks and pinchpoints. Replace both Handrails. REINSPECTION REQUIRED | 11/21/2022 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 8.1 - Machinery space access, lighting, receptacle, and condition | 8.11.4.2.1 (Re-Inspection) | No | No | 8.1.2: Escalator machine spaces(upper and lower pits) shall be kept clean and free from excessive debris. MULTI-YEAR VIOLATION= REINSPECTION REQUIRED TO ENFORCE. > | 11/21/2022 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 7.9 - Steps and upthrust device | 8.6.8.6 | Yes | No | Replace step with broken step treads , only one step | 5/15/2023 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.8.13 Escalator Cleaning | No | No | Perform annual clean down | 5/18/2023 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Escalators | 7.9 - Steps and upthrust device | 8.6.8.6.1 Steps with broken treads shall be repaired or replaced | Yes | Yes | Replace or repair damaged steps | 8/9/2024 |
| A17.1-2016 : Elevators | 10.12 - Pallets, pallet chains, and trusses | 8.6.8.15.12 | Yes | Yes | Replace step chain, stretch beyond acceptable clearances | 8/9/2024 |
| A17.1-2016 : Elevators | 8.12 - Steps, step chains, and trusses | 8.6.8.13 | No | No | Preform annual clean down | 8/9/2024 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.8.1 Escalator Handrails | No | No | replace damaged handrail | 9/11/2025 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.11.6.2(i) Step Demarcation | No | No | provide operational demarcations lights | 9/11/2025 |