Inspection
Inspection Details
Equipment ID
10867
10867
Inspection Date
1/19/2021
1/19/2021
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Thomas McGrath
Thomas McGrath
Mechanic Name
Charles Sheriff
Charles Sheriff
Relief Valve Pressure
Slide
NA
NA
Governor Rope Pull
NA/NA
NA/NA
Door Closing Force
25/20
25/20
External ID
3b31dd6a-b86f-4f86-80cf-14afb1e9683a
3b31dd6a-b86f-4f86-80cf-14afb1e9683a
Location
St. Louis Place
200 N Broadway, St. Louis, MO
Phone: (314) 241-0082
200 N Broadway, St. Louis, MO
Phone: (314) 241-0082
Owner
Attn: Cushman & Wakefield
BPRE St. Louis Holdings, LLP
200 N BROADWAY STE 820, SAINT LOUIS, MO 63102
Phone: (314) 241-0082
Email: tiara.nash@cushwake.com
BPRE St. Louis Holdings, LLP
200 N BROADWAY STE 820, SAINT LOUIS, MO 63102
Phone: (314) 241-0082
Email: tiara.nash@cushwake.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | REpair phone in car | 1/9/2020 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current state certificate in machine room | 3/22/2024 |
| MO Minimum : Elevators | (S) - Fire Service | 8.6.11.1 Monthly Test and Log | No | No | Perform monthly fire service test & document on log | 3/22/2024 |
| MO Minimum : Elevators | (L) - Wire Ropes-Hoisting, Governor and Tiller | (L)12 (Re- Inspection) | Yes | No | Replacehoist ropes--red rouge & reduced diameter within 30 days | 1/26/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6 General Maintenance Methods | No | No | Replace missing duct cover on top of the car | 3/22/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.3.1 Replacement Parts | No | No | Replace missing section of the duct cover on the top of the car | 3/22/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.3.1 Replacement Parts | No | No | Repair/replace greenfield to fan top of the car | 3/22/2024 |
| MO Minimum : Elevators | (L) - Wire Ropes-Hoisting, Governor and Tiller | (L)12 (Re- Inspection) | Yes | No | Replace hoist ropes red rouge reduced diameter within 30 days | 2/8/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) | Yes | No | Repair emergency light in the car | 2/8/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | Repair the phone in the car | 2/8/2023 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current state certificate in machine room | 2/5/2024 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current state certificate in machine room | 1/20/2024 |
| A17.1-2016 : Elevators | 3.20 - Governor rope | 8.6.3.4 | Yes | No | Governor ropes has multiple strands broken needs replacement 30 maximum on respection | 2/14/2024 |
| MO Minimum : Elevators | (S) - Fire Service | 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) | Yes | No | Phase II fire service operation not working 14 day maximum on reinspection | 2/14/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.3.2 Replacement of Suspension Means (Re-Inspection) | Yes | No | Inspection for replacement of governor rope has not been completed yet. State has granted an extension | 6/3/2024 |
| MO Minimum : Elevators | (J) - Counterweights | (J)3 | No | No | Bottom runby for counterweight is 0". Counterweight just touches buffer at top landing. Shorten Ropes for proper clearance. | 4/6/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) | No | No | PM/Repair/callback logs not being consistently documented. | 4/6/2026 |
| MO Minimum : Elevators | (A) - Hoistways | (A)6 | No | No | Hoistway doors have missing or loose guides on 8, 10, 12th floors. Repair/replace as needed. | 4/6/2026 |