Inspection
Inspection Details
Equipment ID
1258
1258
Inspection Date
1/6/2021
1/6/2021
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
James Mueller
James Mueller
Mechanic Name
Douglas Miller
Douglas Miller
Relief Valve Pressure
320
320
Slide
Governor Rope Pull
Door Closing Force
23
23
External ID
391192cc-6060-480b-8b7f-c6a043c21934
391192cc-6060-480b-8b7f-c6a043c21934
Location
O'Fallon City Hall
100 N MAIN ST, O FALLON, MO
Phone: (314) 574-1806
100 N MAIN ST, O FALLON, MO
Phone: (314) 574-1806
Owner
Attn: City of O'Fallon
City of O'Fallon
100 N MAIN ST, O FALLON, MO 63366
Phone: (000) 000-0000
City of O'Fallon
100 N MAIN ST, O FALLON, MO 63366
Phone: (000) 000-0000
Billing
Attn: City of O'Fallon
City of O'Fallon
100 N MAIN ST, O FALLON, MO 63366
Phone: (000) 000-0000
Email: mleonard@ofallon.mo.us
City of O'Fallon
100 N MAIN ST, O FALLON, MO 63366
Phone: (000) 000-0000
Email: mleonard@ofallon.mo.us
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 10/7/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | No | No | The fire extinguisher in the machine room shall have a current test tag. | 10/7/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6 General Maintenance Methods | No | No | 8.6.1.7.5 - Emergency lowering shall be operational. | 10/7/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | No | No | Fire extinguisher in machine room shall have a current test tag. | 1/16/2026 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (1) Minimum Standard | Yes | No | Emergency lowering shall be operational. | 1/17/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | No | No | The fire extinguisher in the machine room shall have a current test tag. The tag is expired. (2nd Notice) | 1/16/2026 |
| A17.1-2016 : Elevators | 1.17 - Standby power operation | 8.6.4.19.7 (Re-Inspection) | Yes | No | Emergency lowering shall be operational. (2nd Notice) | 4/3/2024 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 1/16/2026 |
| A17.1-2016 : Elevators | 1.17 - Standby power operation | 8.6.4.19.7 (Re-Inspection) | Yes | No | Emergency lowering shall be operational. (2nd Notice) Note: This has been reported as a deficiency for the last several years. When operating on emergency lowering, the elevator is trying to run up (pump motor contactor is energized) which is isn't able to do, and also isn't designed to do. It appears this may be a problem introduced when the emergency lowering unit was added to this elevator. | 1/17/2025 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 1/16/2026 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 1/16/2026 |