Inspection
Inspection Details
Equipment ID
506
506
Inspection Date
2/13/2021
2/13/2021
Inspection Type
Alteration
Alteration
Inspector Name
Wayne Ingram
Wayne Ingram
Mechanic Name
Carl Switzer
Carl Switzer
Relief Valve Pressure
390
390
Slide
Governor Rope Pull
Door Closing Force
21
21
External ID
9d32545a-6014-4503-a78e-5ac446d5b09d
9d32545a-6014-4503-a78e-5ac446d5b09d
Location
The Oaks Apartments
321 Hamilton St, Neosho, MO
Phone: (417) 451-5303
Email: NHA4321@AOL.com
321 Hamilton St, Neosho, MO
Phone: (417) 451-5303
Email: NHA4321@AOL.com
Owner
Neosho Housing Authority
321 HAMILTON ST, NEOSHO, MO 64850-1864
321 HAMILTON ST, NEOSHO, MO 64850-1864
Billing
Attn: Neosho Housing Authority
321 HAMILTON ST, NEOSHO, MO 64850-1864
321 HAMILTON ST, NEOSHO, MO 64850-1864
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | conversion - reinspect | Yes | No | Telephone not working--reinspect required | 8/30/2018 |
| conversion | conversion | n/a | No | No | no current certificate | 11/8/2018 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)4 | No | No | Remove empty oil buckets and used rags from Machine room | 8/6/2021 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Current State Operating Permit shall be displayed in the Equipment Room in a non-combustible frame. | 8/6/2021 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | I(1) Pit scavenger pump will be removed. (REINSPECTION within 30 days) | 8/6/2021 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)4 | No | No | Remove empty oil buckets and used rags from Machine room | 3/3/2021 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Current State Operating Permit shall be displayed in the Equipment Room in a non-combustible frame. | 3/3/2021 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | I(1) Pit scavenger pump will be removed. (REINSPECTION within 30 days) | 3/3/2021 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | phone shall work | 10/22/2021 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | repair water leak in machine room | 10/15/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | No | No | No MCP in machine room. | 10/15/2021 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | phone shall work | 10/22/2021 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | 2.27.1.1.6(a)Emergency communications loss monitor shall work. (REINSPECTION REQUIRED) | 9/27/2022 |