Inspection
Inspection Details
Equipment ID
7243
7243
Inspection Date
2/18/2021
2/18/2021
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Daniel Swett
Daniel Swett
Mechanic Name
Brent Davis
Brent Davis
Relief Valve Pressure
Slide
Governor Rope Pull
Door Closing Force
External ID
43cdadbf-ba0e-48ad-b997-6f913e16c578
43cdadbf-ba0e-48ad-b997-6f913e16c578
Location
Eric P Newman Educational Center
320 S EUCLID AVE, SAINT LOUIS, MO
Phone: (314) 747-0740
320 S EUCLID AVE, SAINT LOUIS, MO
Phone: (314) 747-0740
Owner
Attn: Francisco D. Saavedra
WUSM
660 S Euclid Ave, CB 8080, St. Louis, MO 63110
Phone: (314) 747-0740
Fax: (314) 747-0727
Email: francisco.d.saavedra@wustl.edu
WUSM
660 S Euclid Ave, CB 8080, St. Louis, MO 63110
Phone: (314) 747-0740
Fax: (314) 747-0727
Email: francisco.d.saavedra@wustl.edu
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | Demarcation lights are not working. | 4/14/2020 |
| A17.1-1996 : Escalators | 7.5 - Lighting | 805.7 | No | No | Demarcation lighting out - top and bottom. | 4/14/2020 |
| A17.1-2016 : Elevators | 7.7 - Combplate and comb step impact device | 8.6.8.4 | No | No | Combplate impact device (vertical switch) not working at top landing. | |
| A17.1-2016 : Elevators | 7.7 - Combplate and comb step impact device | 8.11.4.1(g) | No | No | Combplate tooth broken at top landing. | |
| A17.1-2016 : Elevators | 7.17 - Step/skirt clearances, panels, and performance index | 8.6.8.3.3 | No | No | Step/skirt performance index over maximum allowable. | |
| A17.1-2016 : Elevators | 7.7 - Combplate and comb step impact device | 8.6.8.4 | No | No | Combplate impact device setting (vertical plane) at top landing of escalator over allowable limit. | |
| A17.1-2016 : Elevators | 7.7 - Combplate and comb step impact device | 8.6.8.4 | No | No | Combplate impact device (vertical switch) not working at top landing. | |
| A17.1-2016 : Elevators | 7.17 - Step/skirt clearances, panels, and performance index | 8.6.8.3.3 | No | No | Step/skirt performance index over maximum allowable. | |
| A17.1-1996 : Escalators | 7.5 - Lighting | 805.7 | No | No | Demarcation lighting not working (both top and bottom). | |
| A17.1-1996 : Escalators | 7.1 - General fire protection | 801 | No | No | Observed opening in deck. Exterior deck plates sliding down, creating opening. | |
| A17.1-2016 : Elevators | 7.7 - Combplate and comb step impact device | 8.6.8.4 | No | No | Combplate impact device (vertical switch) not working at top landing. | |
| A17.1-2016 : Elevators | 7.17 - Step/skirt clearances, panels, and performance index | 8.6.8.3.3 | No | No | Step/skirt performance index over maximum allowable. | |
| A17.1-1996 : Escalators | 7.5 - Lighting | 805.7 | No | No | Demarcation lighting not working (both top and bottom). | |
| A17.1-2016 : Elevators | 7.3 - Handrails | 8.6.8.1 | No | No | Handrails cracking, presenting pinch points. Both handrails. |