Inspection
Inspection Details
Equipment ID
11828
11828
Inspection Date
7/16/2018
7/16/2018
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
David Folkert
David Folkert
Mechanic Name
Bobby Joe Mehrens
Bobby Joe Mehrens
Relief Valve Pressure
520
520
Slide
Governor Rope Pull
Door Closing Force
25
25
External ID
8a7d94e2-9ab1-4a97-94b3-89562a82a0fc
8a7d94e2-9ab1-4a97-94b3-89562a82a0fc
Location
Stoney Creek Inn
1201 N WOODBINE RD, SAINT JOSEPH, MO
1201 N WOODBINE RD, SAINT JOSEPH, MO
Owner
Stoney Creek Inn
1201 N WOODBINE RD, SAINT JOSEPH, MO 64506-2466
1201 N WOODBINE RD, SAINT JOSEPH, MO 64506-2466
Billing
Attn: Stoney Creek Inn
1201 N WOODBINE RD, SAINT JOSEPH, MO 64506-2466
1201 N WOODBINE RD, SAINT JOSEPH, MO 64506-2466
Violations
Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
---|---|---|---|---|---|---|
A17.1-2016 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 8.6.11.1 Firefighters’ Emergency Operation Documentation | Test firefighters operation monthly and provide log in machine room. | 9/22/2020 | ||
A17.1-1996 : Elevators | 2.1 - Access to machine space | 101.3b | Machine room access door needs to be self-closing. | 9/22/2020 | ||
A17.1-1996 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 211.7 Firefighter' Service Operating Procedures | Post firefighters instructions next to hall fire keyswitch. | 9/22/2020 | ||
A17.1-1996 : Elevators | 2.14 - Code data plate | 215 | Post code data plate on controller or mainline disconnect. | 9/22/2020 | ||
A17.1-1996 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | Post emergency evacuation of passengers form inside machine room. | 9/22/2020 | ||
A17.1-2016 : Elevators | 2.4 - Machine space | 8.6.4.8 Machine Room and Machinery Space | Remove non elevator related material from machine room. Remove trash, rags and flammable items. | 9/22/2020 | ||
A17.1-1996 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | Provide test tag for record of annual pressure relief test. | 9/22/2020 | ||
A17.1-1996 : Elevators | 1.6 - Car emergency signal | 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | x | Emergency phone does not operate | 1/5/2022 | |
A17.1-1996 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 211.7 Firefighter' Service Operating Procedures | Post firefighter instructions next to hall fire keyswitch | 11/8/2021 | ||
A17.1-1996 : Elevators | 1.18 - Restricted opening of car or hoistway doors | 1001.2(a)(18) | x | Car door restrictor does not function | 1/5/2022 | |
A17.1-2016 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 8.6.11.1 Firefighters’ Emergency Operation Documentation | Test and log firefighter operation monthly | 11/8/2021 | ||
A17.1-1996 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 106.1e Illumination of Pits | Install pit collection containers for cylinder drain lines and remove waste oil from pit floor. | 11/8/2021 | ||
A17.1-1996 : Elevators | 1.5 - Car lighting and receptacles | 204.7a (3)(a) Standby Illumination in the car. (Re-Inspection) | x | Emergency light does not illuminate when normal power for car lights is off. | 6/15/2023 | |
MO Minimum : Elevators | (H) - Machine Rooms | (H)4 | REPAIR HOLE IN MACHINE ROOM CELING WHERE THE SHEETROCK WAS REMOVED TO DO A REPAIR ABOVE THE CELING | 8/12/2024 | ||
MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)7 | DOOR CLOSING FORCE IS >30 LBS | 8/12/2024 |