Inspection
Inspection Details
Equipment ID
7714
7714
Inspection Date
3/2/2021
3/2/2021
Inspection Type
5 Year Annual Inspection
5 Year Annual Inspection
Inspector Name
Clyde Johnson
Clyde Johnson
Mechanic Name
James DeBell
James DeBell
Relief Valve Pressure
Slide
19
19
Governor Rope Pull
110/550
110/550
Door Closing Force
27
27
External ID
518414ce-fd07-4c4b-b1c1-9ce7df038b96
518414ce-fd07-4c4b-b1c1-9ce7df038b96
Location
The Westin Hotel-St. Louis
811 Spruce St, St. Louis, MO
Phone: (314) 621-2000
811 Spruce St, St. Louis, MO
Phone: (314) 621-2000
Owner
Attn: The Westin St. Louis
HEI St. Louis LLC
811 SPRUCE ST, SAINT LOUIS, MO 63102
Phone: (314) 552-5810
Email: Tom.dietz@westinstlouishotel.com
HEI St. Louis LLC
811 SPRUCE ST, SAINT LOUIS, MO 63102
Phone: (314) 552-5810
Email: Tom.dietz@westinstlouishotel.com
Billing
Same as Owner
Violations
Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
---|---|---|---|---|---|---|
A17.1-1996 : Elevators | 1.18 - Restricted opening of car or hoistway doors | 111.5 Restricted Opening of Hall/Car Doors | x | Car door restrictor does not work. | 4/15/2021 | |
A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | Post current operating certificate in machine room. | |||
A17.1-1996 : Elevators | 1.6 - Car emergency signal | 211.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | x | Emergency phone line is not working. Re-inspection required | 3/13/2023 | |
A17.1-1996 : Elevators | 1.18 - Restricted opening of car or hoistway doors | 111.5 Restricted Opening of Hall/Car Doors | x | Car door restrictor shall be made operable | 2/22/2024 | |
MO Minimum : Elevators | (I) - Pits | (I)1 | Elevator pit shall be kept clean and dry, this elevator pit has water standing and has damaged pit equipment | |||
MO Minimum : Elevators | (I) - Pits | (I)2 | The pit channels are very corroded due to excessive water in the pit | |||
MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | x | Elevator cab phone does not work, needs repaired. Re-inspection required | 9/3/2024 | |
MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | x | Elevators connected to an emergency generator shall be tested for operation on emergency power. Re-inspection required | 9/3/2024 | |
A17.1-2016 : Elevators | 1.18 - Restricted opening of car or hoistway doors | 8.6.4.13.1(l)(Door Restrictor) | x | Car door restrictor shall be made operable. Re-inspection required | 9/3/2024 | |
MO Minimum : Elevators | (I) - Pits | (I)2 | The pit channels are every corroded due to excessive water in the pit | |||
A17.1-1996 : Elevators | 1.18 - Restricted opening of car or hoistway doors | 111.5 Restricted Opening of Hall/Car Doors | x | Car door restrictor shall be made operable. Re-inspection required | 2/3/2025 | |
MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | x | Elevator cab phone does not work, needs repaired. Re-inspection required | 2/3/2025 | |
A17.1-2016 : Elevators | 1.18 - Restricted opening of car or hoistway doors | 8.6.4.13.1(l)(Door Restrictor) | x | Car door restrictor is not working. Re-inspection required |