Inspection
Inspection Details
Equipment ID
16716
16716
Inspection Date
2/8/2021
2/8/2021
Inspection Type
Major Alteration
Major Alteration
Inspector Name
James Mueller
James Mueller
Mechanic Name
Eric Sievers
Eric Sievers
Relief Valve Pressure
500
500
Slide
Governor Rope Pull
Door Closing Force
22
22
External ID
0708ee43-4f72-43af-876a-e009619af882
0708ee43-4f72-43af-876a-e009619af882
Location
505 Washington Bldg-this bldg is vacant
505 Washington Ave, St. Louis, MO
Phone: (314) 630-0266
505 Washington Ave, St. Louis, MO
Phone: (314) 630-0266
Owner
Attn: Roberto Chacon
P+F Properties LLC
1167 Hillside Dr, St. Louis, MO 63117
Phone: (314) 691-2900
Email: rchacon@chaconconstruction.com
P+F Properties LLC
1167 Hillside Dr, St. Louis, MO 63117
Phone: (314) 691-2900
Email: rchacon@chaconconstruction.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| A17.1-2016 : Elevators | 2.1 - Access to machine space | 8.10.3.2.2(d) | Yes | No | A 2 hour fire rated machine room door with a self-closing and self-locking door shall be provided. | 2/11/2022 |
| A17.1-2016 : Elevators | 2.7 - Fire Extinguisher | 8.10.3.2.2(l) | Yes | No | An ABC type fire extinguisher shall be provided. | 2/11/2022 |
| A17.1-2016 : Elevators | 2.3 - Lighting and receptacles | 8.10.3.2.2(h) | Yes | No | Code compliant machine room lighting shall be provided. | 2/11/2022 |
| A17.1-2016 : Elevators | 2.3 - Lighting and receptacles | 8.10.3.2.2(h) | Yes | No | A GFI receptacle shall be provided in the machine room. | 2/11/2022 |
| A17.1-2016 : Elevators | 2.6 - Ventilation | 8.10.3.2.2(k) | Yes | No | Provide proper machine room ventilation. | 2/11/2022 |
| MO Minimum : Elevators | (S) - Fire Service | (S)1 | Yes | Yes | Install and test all smoke detectors and phases of fire service. | 2/11/2022 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (2)(C) Re-Inspection Required to Enforce. | Yes | No | 8.10.3.2.1(d) - Cab flooring shall be installed | 3/2/2023 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (2)(C) Re-Inspection Required to Enforce. | Yes | No | 8.10.3.2.2(r) - Disconnects shall be installed at proper NEC specifications | 3/2/2023 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (2)(C) Re-Inspection Required to Enforce. | Yes | No | 8.10.3.2.3(m) - All hoistway duct covers and electrical box covers need to be installed. | 3/2/2023 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (2)(C) Re-Inspection Required to Enforce. | Yes | No | 8.10.3.2.2(i) - Patch the holes in the machine room walls. | 3/2/2023 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (2)(C) Re-Inspection Required to Enforce. | Yes | No | 8.10.3.2.4(b) - Install missing gib on top floor hoistway door. | 3/2/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.13 - Door systems | Yes | No | Car door restrictor shall operate. | 3/2/2023 |
| MO Minimum : Elevators | (S) - Fire Service | 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) | Yes | No | Firemans' Phase 1 shall operate. | 3/2/2023 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (2)(C) Re-Inspection Required to Enforce. | Yes | No | 8.10.3.2.2(d) - A 2 hour fire rated machine room door with a self-closing and self-locking door shall be provided. | 3/2/2023 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (2)(C) Re-Inspection Required to Enforce. | Yes | No | 8.10.3.2.2(I) - An ABC type fire extinguisher shall be provided. | 3/2/2023 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (2)(C) Re-Inspection Required to Enforce. | Yes | No | 8.10.3.2.2(h) - Code compliant machine room lighting shall be provided. | 3/2/2023 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (2)(C) Re-Inspection Required to Enforce. | Yes | No | 8.10.3.2.2(h) - A GFI receptacle shall be provided in the machine room. | 3/2/2023 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (2)(C) Re-Inspection Required to Enforce. | Yes | No | 8.10.3.2.2(k) - Provide proper machine room ventilation. | 3/2/2023 |
| MO Minimum : Elevators | (S) - Fire Service | (S)1 | Yes | Yes | Install and test all smoke detectors and phases of fire service. | 3/2/2023 |
| A17.1-2016 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 2.27.3.2 Phase I Operation Recall by Initiating Device | Yes | Yes | The fire alarm initiating device at the third landing shall signal the elevator to go into fire service operation. Note: When the device was activated, a building alarm occurred, but the elevator fire service was not initiated. | 3/24/2023 |
| A17.1-2016 : Elevators | 1.6 - Car emergency signal | 2.27.1.1.6 Verification of Telephone Operability | Yes | No | Emergency communications loss monitor shall work. | 3/26/2024 |
| A17.1-2016 : Elevators | 2.40 - Maintenance Records | 8.6.1.2.2 On-Site Documentation | No | No | A code compliant MCP and related on-site documentation shall be provided in the machine room. Note: No 2022, and 2023 is blank. | 4/2/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.13 - Door systems | No | No | Replace the missing door guide(s). | 4/2/2026 |
| A17.1-2016 : Elevators | 3.12 - Pipes, wiring, and ducts | 2.8 | No | No | 4x4 electrical box on cartop needs to have wiring inside box and cover installed. | 4/2/2026 |
| A17.1-2016 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 8.6.4.7 Cleaning of Pits | No | No | Pit shall be kept clean. Remove excess debris/oil from pit floor. | 4/2/2026 |
| A17.1-2016 : Elevators | 1.6 - Car emergency signal | 2.27.1.1.6 Verification of Telephone Operability | Yes | No | Emergency communications loss monitor shall work. - Not corrected at time 3/26/24 re-inspection. | 1/14/2025 |
| A17.1-2016 : Elevators | 3.12 - Pipes, wiring, and ducts | 2.8 | No | No | Replace missing 4x4 box cover on side hoistway wall at midway point of hoistway. | 4/2/2026 |
| A17.1-2016 : Elevators | 1.18 - Restricted opening of car or hoistway doors | 8.6.4.13.1(l)(Door Restrictor) | Yes | No | The car door restrictor shall be functional. | 7/24/2025 |
| A17.1-2016 : Elevators | 1.6 - Car emergency signal | 2.27.1.1.6 Verification of Telephone Operability | Yes | No | Emergency communications loss monitor shall work. This violation has not been repaired since previous inspection. This is the final notice for this violation. Failure to correct violation immediately may result in elevator being locked out of service until corrected. | 7/24/2025 |