Inspection
Inspection Details
Equipment ID
7507
7507
Inspection Date
3/26/2021
3/26/2021
Inspection Type
5 Year Annual Inspection
5 Year Annual Inspection
Inspector Name
Angelo Consiglio
Angelo Consiglio
Mechanic Name
Matthew Fernandez
Matthew Fernandez
Relief Valve Pressure
Slide
2 1/2
2 1/2
Governor Rope Pull
450/975
450/975
Door Closing Force
29
29
External ID
7cdaafc0-c943-42aa-ab9a-29920b6ff107
7cdaafc0-c943-42aa-ab9a-29920b6ff107
Location
Revival STL Construction , LLC
5522 DELMAR BLVD, SAINT LOUIS, MO
Phone: (417) 425-1346
5522 DELMAR BLVD, SAINT LOUIS, MO
Phone: (417) 425-1346
Owner
Attn: Revival STL Construction, LLC
Revival STL Construction, LLC
PO Box 46721, St. Louis, MO 63146
Phone: (314) 852-6755
Email: anshul@revivalstl.com
Revival STL Construction, LLC
PO Box 46721, St. Louis, MO 63146
Phone: (314) 852-6755
Email: anshul@revivalstl.com
Billing
Same as Owner
Violations
Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
---|---|---|---|---|---|---|
conversion | conversion | n/a | Door closing force shall be less than 30 | 6/3/2019 | ||
conversion | conversion | conversion - reinspect | x | On Phase II door does not close when door open button is released | 5/8/2019 | |
conversion | conversion | n/a | Fill All Voids in hoisway in pit area - 1 near top of hoistway | 6/3/2019 | ||
MO Minimum : Elevators | (S) - Fire Service | (S)1 | x | Remove the Phase 1 fire service key switch at the basement level. | 7/17/2019 | |
MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 5/15/2020 | ||
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | The machine room fire extinguisher shall have a current test tag. | 5/15/2020 | ||
MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)7 | The door closing force shall be adjusted so it does not exceed 30 pounds. | 5/15/2020 | ||
MO Minimum : Elevators | (A) - Hoistways | (A)13 | The holes in the pit wall, and near the top of the hoistway shall be sealed with approved solid materials. | 5/15/2020 | ||
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - Car Emergency Systems - 8.6.4.15 (bell, phone & Emergency lighting) | x | The emergency lighting shall be operational. | 8/14/2020 | |
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - Car Emergency Systems - 8.6.4.15 (bell, phone & Emergency lighting) | x | The alarm bell shall be operational on auxiliary power. | 8/14/2020 | |
MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)7 | Door closing force shall be adjusted, not to exceed 30 pds. | 7/25/2020 | ||
MO Minimum : Elevators | (A) - Hoistways | (A)13 | Seal holes in pit wall and near top of hoistway. | 7/25/2020 | ||
MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | Post operating certificate in equipment room. | 4/6/2021 | ||
MO Minimum : Elevators | (S) - Fire Service | 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) | x | Repair inoperable audible and visual Phase I indicators | 4/9/2024 | |
MO Minimum : Elevators | (S) - Fire Service | 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) | x | Repair Phase II key switch. Hold position not functioning | 4/9/2024 | |
MO Minimum : Elevators | (S) - Fire Service | 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) | x | Stop switch not overridden in Phase 1 | 4/9/2024 | |
MO Minimum : Elevators | (S) - Fire Service | 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) | x | Car not returning to Phase I when Phase II key is switched to off | 4/9/2024 | |
MO Minimum : Elevators | (S) - Fire Service | 211.3a(8) Visual and audible signal | x | x | Repair inoperable audible and visual Phase I indicators. Initially sited 5/26/23. | 5/1/2024 |
MO Minimum : Elevators | (S) - Fire Service | (S)1 | x | x | Repair Phase II key switch. Hold position not functioning. Initially sited 5/26/23. | 5/1/2024 |
MO Minimum : Elevators | (S) - Fire Service | (S)1 | x | x | Stop switch not overridden in Phase 1. Initially sited 5/26/23. | 5/1/2024 |
MO Minimum : Elevators | (S) - Fire Service | (S)1 | x | x | Car not returning to Phase I when Phase II key is switched to off. Initially sited 5/26/23. | 5/1/2024 |
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | The fire extinguisher in the machine room shall be serviced, the last annual service tag indicates it was serviced in 2022. | 5/15/2024 | ||
MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | The elevator machine room door shall be self-closing/self-locking and shall be operable from the interior space without the use of a key. | 5/15/2024 | ||
MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | x | The testing has not been completed on the elevator at this time, the elevator was placed out of service. Only a machine room inspection was performed, a full inspection shall be performed before the annual is completed. Reinspection is required. | 5/1/2024 | |
MO Minimum : Elevators | (S) - Fire Service | 211.7 Firefighters Operations/Signage | Provide signage to meet the code date of the Fire recall system (No Hold for this vintage | 5/15/2024 | ||
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.3.1 Replacement Parts | Provide 2 separate car light sources | 5/15/2024 | ||
MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | The elevator machine room door shall be self-closing/self-locking and shall be operable from the interior space without the use of a key. | 5/15/2024 |