Inspection
Inspection Details
Equipment ID
5730
5730
Inspection Date
3/25/2021
3/25/2021
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Michael Bailey
Michael Bailey
Mechanic Name
Jeff Setchfield
Jeff Setchfield
Relief Valve Pressure
360
360
Slide
Governor Rope Pull
Door Closing Force
21
21
External ID
c2d6d655-ea2c-4549-8755-43f00d0d0d30
c2d6d655-ea2c-4549-8755-43f00d0d0d30
Location
9909 Clayton Rd Office Bldg
9909 CLAYTON RD, SAINT LOUIS, MO
Phone: (314) 995-7200
9909 CLAYTON RD, SAINT LOUIS, MO
Phone: (314) 995-7200
Owner
Attn: UNK
Boulevard Investment Corp
9909 Clayton Road, Ste 224, SAINT LOUIS, MO 63124
Phone: (573) 268-8570
Email: snipsa@gmail.com
Boulevard Investment Corp
9909 Clayton Road, Ste 224, SAINT LOUIS, MO 63124
Phone: (573) 268-8570
Email: snipsa@gmail.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency light and alarm bell are not working. | 4/2/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency light and alarm bell do not work. | 3/25/2021 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Remove water from pit. | 3/24/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.13 - Door systems | Yes | No | The car door restrictor device shall be repaired so that it will properly catch and restrict opening of the car doors to a maximum of 4 inches when the car is away from the landing zone. Currently, the battery backup system for the door restrictor is not operating correctly which is resulting in a nuisance alarm sounding continuously. Reinspection is required. | 4/21/2023 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | The elevator pit floor is covered in water. The elevator pit shall be kept clean and dry. Sealing of the pit or some sort of water containment/diversion channel shall be constructed. | 3/24/2026 |
| MO Minimum : Elevators | (I) - Pits | (I)8 | No | No | The sump pump hole in the pit shall be provided with a noncombustible cover that is flush with the pit floor. There is currently no cover provided. | 3/24/2026 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | The elevator alarm bell inside the elevator is not working. Check and repair the alarm bell for proper operation and passenger safety. | 4/21/2023 |
| MO Minimum : Elevators | (I) - Pits | (I)8 | No | No | The sump pump hole in the pit shall be provided with a non combustible cover that is flush with the pit floor. There is currently no cover provided | 5/10/2023 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Provide means to keep pit floor dry (water). | 3/24/2026 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current State Elevator Certificate. | 3/24/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.5.5.1 Examination and Maintenance | Yes | No | Car failed 15 minute stand test. Tech determined that it was going back through the valve, repair as needed, retest. | 3/24/2026 |