Inspection
Inspection Details
Equipment ID
17343
17343
Inspection Date
3/25/2021
3/25/2021
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Michael Bailey
Michael Bailey
Mechanic Name
Jeff Setchfield
Jeff Setchfield
Relief Valve Pressure
650
650
Slide
Governor Rope Pull
Door Closing Force
20
20
External ID
7ca07f61-2959-4aa6-ae8b-9041f6dde31e
7ca07f61-2959-4aa6-ae8b-9041f6dde31e
Location
Cahill House
1919 O'Fallon St, St. Louis, MO
Phone: (314) 436-5061
1919 O'Fallon St, St. Louis, MO
Phone: (314) 436-5061
Owner
Attn: Cahill House
Cahill House
1919 O'Fallon St, St. Louis, MO 63106
Phone: (314) 436-5061
Email: cahillhouse@mccormackbaron.com
Cahill House
1919 O'Fallon St, St. Louis, MO 63106
Phone: (314) 436-5061
Email: cahillhouse@mccormackbaron.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| A17.1-1996 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | No | No | Provide missing on-site documents for maintenance control program. | 11/12/2025 |
| A17.1-1996 : Elevators | 11 CSR 40-5.090 Inspection and Testing | 8.6.5.16.5 Over Speed Valve Testing | No | No | OSV is not sealed. Perform test on or before next annual inspection. | 11/12/2025 |
| A17.1-1996 : Elevators | 2.5 - Housekeeping | 1206.2c (Clean Car Tops) | No | No | Clean car top. | 11/12/2025 |
| A17.1-1996 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 1206.2a (Pits and Hoistways) | No | No | Clean down hoist way. | 11/12/2025 |
| A17.1-1996 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 1206.2a (Pits and Hoistways) | No | No | Clean pit. | 11/12/2025 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current State Elevator Certificate. | 11/12/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | No | No | Provide current year tested fire extinguisher in the elevator machine room. | 11/12/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | Abate black mold in the hoistway, 2nd floor, back wall. | 11/12/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.5.5.2 Oil Leakage Collection | No | No | Provide means to collect oil from jack in the pit (has hose). | 11/12/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | Provide existing phone to work. | 11/12/2025 |
| A17.1-2016 : Elevators | 3.10 - Hoistway construction | 8.6.4.7 Cleaning of Hoistways | No | No | Need to abate mold on back wall of hoistway at 2nd floor |