Inspection
Inspection Details
Equipment ID
10475
10475
Inspection Date
3/31/2021
3/31/2021
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Michial Linenfelser
Michial Linenfelser
Mechanic Name
Bradley Tramel
Bradley Tramel
Relief Valve Pressure
Slide
Na
Na
Governor Rope Pull
Na
Na
Door Closing Force
13
13
External ID
b316862d-7f19-4302-aa0b-3fe2e363321c
b316862d-7f19-4302-aa0b-3fe2e363321c
Location
Pierre Chouteau Condos
4440 Lindell Blvd, St. Louis, MO
Phone: (314) 289-8816
Alt Phone: (314) 629-5175
4440 Lindell Blvd, St. Louis, MO
Phone: (314) 289-8816
Alt Phone: (314) 629-5175
Owner
Attn: Pierre Chouteau Condos
Pierre Chouteau Condos
4440 LINDELL BLVD, SAINT LOUIS, MO 63108-2449
Pierre Chouteau Condos
4440 LINDELL BLVD, SAINT LOUIS, MO 63108-2449
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | 2. Horizontally sliding or single section swinging doors of automatic elevators must be provided with door closers arranged to close an open door automatically if the car leaves the landing zone for any reason. During inspection the 3rd floor (4th Landing) & 4th floor ( 5th Landing) doors weren?t free enough to pass the door closing inspection. | 7/23/2018 |
| conversion | conversion | conversion - reinspect | Yes | No | 4. The code under which this major alteration was performed requires means of two-way conversation on all automatic elevators. Phone isn?t functioning. | 3/6/2019 |
| conversion | conversion | n/a | No | No | 3. Verify that the top emergency exit is hinged or otherwise attached to the car. This exit is not and shall be attached to car by some means. | 7/23/2018 |
| conversion | conversion | n/a | No | No | 1. All excess lubricant shall be cleaned from the equipment. Containers used to catch leakage shall not be allowed to overflow. Machine has gear oil on it from varies leaks, with the brake drum having oil on it, traction drive sheave having oil on it, etc. | 7/23/2018 |
| conversion | conversion | n/a | No | No | 5. Emergency operation of signaling devices, lighting, communication and ventilation, shall be maintained. | 7/23/2018 |
| A17.1-1996 : Elevators | 2.19 - Gears, bearings, and flexible couplings | 1206.1a | No | No | 1) All excess lubricant shall be cleaned from the equipment. Machine has gear oil on it from varies leaks, with the brake drum having oil on it, traction drive sheave having oil on it, etc. | 5/1/2019 |
| A17.1-1996 : Elevators | 1.18 - Restricted opening of car or hoistway doors | 1001.2(a)(18) | Yes | No | The car door restrictor device shall be adjusted so that it will properly catch and restrict opening of the car doors to a maximum of 4 inches when the car is away from the landing zone. Reinspection required. | 5/25/2021 |
| A17.1-1996 : Elevators | 1.5 - Car lighting and receptacles | 204.7 | No | No | The emergency light fixture inside the elevator is not operational and needs to be repaired. | 3/16/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | Secure pit ladder to pit floor or replace | 11/4/2025 |
| MO Minimum : Elevators | (S) - Fire Service | 211.8 Switch Keys | Yes | No | All fire recall keys shall be keyed alike (FEOK1) | 3/11/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | Yes | Yes | Replace car buffer pit channel. Channel rusted out causing car buffer to lean | 3/11/2025 |
| MO Minimum : Elevators | (S) - Fire Service | 211.8 Switch Keys | No | No | All ?re recall keys shall be keyed alike (FEOK1) | 11/4/2025 |