Inspection
Inspection Details
Equipment ID
13802
13802
Inspection Date
4/6/2021
4/6/2021
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Michael Gallaher
Michael Gallaher
Mechanic Name
Bradley Tramel
Bradley Tramel
Relief Valve Pressure
Slide
NA
NA
Governor Rope Pull
NA
NA
Door Closing Force
23
23
External ID
c45377e3-d658-4571-819c-45e0b38929f2
c45377e3-d658-4571-819c-45e0b38929f2
Location
Cosand Center
330 S Broadway, St. Louis, MO
Phone: (314) 539-5191
330 S Broadway, St. Louis, MO
Phone: (314) 539-5191
Owner
Attn: Tina Ripple
Bamboo Broadway LLC c/o Intelica
600 Emerson Rd, Ste 210, Creve Coeur, MO 63141
Phone: (314) 200-4347
Alt Phone: (314) 270-5991 Ext: 141
Email: tripple@intcre.com
Bamboo Broadway LLC c/o Intelica
600 Emerson Rd, Ste 210, Creve Coeur, MO 63141
Phone: (314) 200-4347
Alt Phone: (314) 270-5991 Ext: 141
Email: tripple@intcre.com
Billing
Attn: Tina Ripple
Bamboo Broadway LLC c/o Intelica
600 Emerson Rd, Ste 210, Creve Coeur, MO 63141
Phone: (314) 200-4347
Alt Phone: (314) 270-5991 Ext: 141
Email: ap@intcre.com
Bamboo Broadway LLC c/o Intelica
600 Emerson Rd, Ste 210, Creve Coeur, MO 63141
Phone: (314) 200-4347
Alt Phone: (314) 270-5991 Ext: 141
Email: ap@intcre.com
Violations
Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
---|---|---|---|---|---|---|
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | x | Car emergency telephone needs to be programmed to the current elevator contractor. | 6/1/2020 | |
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | The fire extinguisher in the machine room is expired. | 3/29/2019 | ||
MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 3/29/2019 | ||
A17.1-2016 : Elevators | 2.7 - Fire Extinguisher | n/a | The machine room fire extinguisher shall have a current test tag. | 3/29/2019 | ||
A17.1-2016 : Elevators | 3.2 - Car top light and outlet | 8.11.2.1.3(b) | The light on the top of the car shall be operational. | 3/29/2019 | ||
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - Car Emergency Systems - 8.6.4.15 (bell, phone & Emergency lighting) | x | The in car emergency light shall be operational | 8/12/2020 | |
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - Car Emergency Systems - 8.6.4.15 (bell, phone & Emergency lighting) | x | The alarm bell shall be operational on auxiliary power. | 8/12/2020 | |
A17.1-2016 : Elevators | 1.13 - Emergency exit | 2.14.1.10 | x | x | The side emergency exits shall be permanently fixed in the closed position. (The cab has been altered, possibly in 2015 when the car was modernized. Access to the side emergency exits are now blocked) | 8/12/2020 |
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.7 - Fire Extinguisher | 8.6.1.6.5 | Fire extinguisher in machine room is expired. | 10/21/2022 | ||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.6 - Car emergency signal | 8.11.2.1.1(f) (Insp code) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | x | Emergency phone line does not work. | 4/29/2022 | |
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 2.2.5 Illumination of Pits | Pit light does not work. | 10/21/2022 | ||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | Post current operating certificate in machine room. | 10/21/2022 | ||
MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | Pit light does not work | 10/21/2022 | ||
MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | x | Emergency phone does not work, phone doesn't respond when button is pushed. Re-inspection required | 10/21/2022 | |
MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | Machine room door needs to be self locking & self closing. | 10/21/2022 | ||
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | The fire extinguisher is expired, needs replaced or serviced. | 10/21/2022 | ||
MO Minimum : Elevators | (A) - Hoistways | (A)13 | Holes in the hoistway need to covered and fireproofed | 10/21/2022 | ||
MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | x | Emergency phone does not work. Has ring tone but no answer. Repair or replace | 3/31/2023 |