Inspection
Inspection Details
Equipment ID
18539
18539
Inspection Date
5/6/2021
5/6/2021
Inspection Type
5 Year Annual Inspection
5 Year Annual Inspection
Inspector Name
David Folkert
David Folkert
Mechanic Name
Craig Loveall
Craig Loveall
Relief Valve Pressure
Slide
Na
Na
Governor Rope Pull
70/250
70/250
Door Closing Force
22
22
External ID
e327866b-028e-4046-9044-07794b85891d
e327866b-028e-4046-9044-07794b85891d
Location
YWCA-St Joseph
304 N 8TH ST, SAINT JOSEPH, MO
Phone: (816) 232-4481
304 N 8TH ST, SAINT JOSEPH, MO
Phone: (816) 232-4481
Owner
Attn: Tammy Killin, CEO
YWCA-St Joseph
304 N 8TH ST, SAINT JOSEPH, MO 64501
Phone: (816) 232-4481
Email: mgrooms@ywcasj.org
YWCA-St Joseph
304 N 8TH ST, SAINT JOSEPH, MO 64501
Phone: (816) 232-4481
Email: mgrooms@ywcasj.org
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | Replace traveling cable supporting means. Support shows signs of wear. | 7/25/2018 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)10 Car Floors | No | No | Need to replace or repair flooring in order to eliminate tripping hazard. | 6/12/2019 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - Car Emergency Systems - 8.6.4.15 (bell, phone & Emergency lighting) | Yes | No | Emergency phone does not operate. | 6/4/2019 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.2.1 General Maintenance Requirements Documentation | No | No | No MCP | 7/21/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | No | No | No maintenance records on site | 7/21/2022 |
| MO Minimum : Elevators | (A) - Hoistways | (A)16 | No | No | Install cover on electrical box located on top of the elevator | 7/21/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.4.9 Cleaning of Top of Cars | No | No | Remove debris and spare parts from the top of the elevator | 7/21/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.4.7 Cleaning of Hoistway and Pit | No | No | Remove debris from the elevator pit | 7/21/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.7 Signs and Data Plates | No | No | Post In Case of Fire signage next to hall button fixture at each landing | 7/21/2022 |
| MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | No | No | Pit light does not illuminate | 7/21/2023 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | EMERGENCY ALARN BELL NOT WORKING UNDER BATTERY POWER | 8/26/2024 |