Inspection
Inspection Details
Equipment ID
8999
8999
Inspection Date
7/19/2018
7/19/2018
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Jeffrey Krug
Jeffrey Krug
Mechanic Name
Jeffrey Carpenter
Jeffrey Carpenter
Relief Valve Pressure
530
530
Slide
Governor Rope Pull
Door Closing Force
15
15
External ID
2ebf0f17-726d-4925-988a-8369f3e178a0
2ebf0f17-726d-4925-988a-8369f3e178a0
Location
Americas Best Value Inn
1100 LUMIERE PLACE BLVD, SAINT LOUIS, MO
1100 LUMIERE PLACE BLVD, SAINT LOUIS, MO
Owner
Americas Best Value Inn
1100 LUMIERE PLACE BLVD, SAINT LOUIS, MO 63102-2225
1100 LUMIERE PLACE BLVD, SAINT LOUIS, MO 63102-2225
Billing
Attn: Americas Best Value Inn
1100 LUMIERE PLACE BLVD, SAINT LOUIS, MO 63102-2225
1100 LUMIERE PLACE BLVD, SAINT LOUIS, MO 63102-2225
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (H) - Machine Rooms | (H)8 | No | No | Multiple exposed wires running through machine room | 10/23/2019 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | Machine room door shall be self closing and self locking | 10/23/2019 |
| MO Minimum : Elevators | (A) - Hoistways | (A)3 | No | No | Bottom floor sill bowed not allowing hoistway door to be self closing | 10/23/2019 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)8 Car Lighting | No | No | Emergency light in car doesn't work | 10/23/2019 |
| MO Minimum : Elevators | (N) - Guide Rails | (N)1 | No | No | Reduced running clearance. Elevator door clutch scrapes fascia when running up. Check guide rails for adjustment. | 1/15/2021 |
| MO Minimum : Elevators | (A) - Hoistways | (A)3 | No | No | First Floor Hoistway sill is bowed preventing unassisted closing of hoistway door | 8/8/2022 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Alarm bell in car does not work | 8/8/2022 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)4 | No | No | Machine Room is not to contain any items not related to the operation of the elevator | 8/8/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.13 - Door systems | Yes | No | A17.1 1984 Rule 110.11e - Hoistway door panels shall not have a gap larger than 3/8" between the door and frame. | 8/15/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) | No | No | A written Maintenance Control Program shall be in place to maintain the equipment in compliance with the requirements of Section 8.6. | 11/22/2025 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)4 | No | No | Articles or materials not necessary for the maintenance or operation of the elevator shall not be stored in machine room. | 11/22/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.3.1 Replacement Parts | Yes | No | Replace missing fascia between the second and third floor. | 1/12/2026 |