Inspection
Inspection Details
Equipment ID
1306
1306
Inspection Date
5/10/2021
5/10/2021
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Christopher "RED" Staton
Christopher "RED" Staton
Mechanic Name
Doug Price
Doug Price
Relief Valve Pressure
425
425
Slide
Governor Rope Pull
Door Closing Force
20
20
External ID
87b6a7fd-d3e6-4ed7-8694-8763d28ad8ff
87b6a7fd-d3e6-4ed7-8694-8763d28ad8ff
Location
Carthage Jr High
827 E Centennial Ave, Carthage, MO
Phone: (417) 359-7015
Email: danhill@carthagetigers.org
827 E Centennial Ave, Carthage, MO
Phone: (417) 359-7015
Email: danhill@carthagetigers.org
Owner
Attn: Carthage R-9 School District
Carthage R-9 School District
710 LYON ST, CARTHAGE, MO 64836
Phone: (417) 359-7014
Email: schmittb@carthagetigers.org
Carthage R-9 School District
710 LYON ST, CARTHAGE, MO 64836
Phone: (417) 359-7014
Email: schmittb@carthagetigers.org
Billing
Same as Owner
Violations
Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
---|---|---|---|---|---|---|
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - Car Emergency Systems - 8.6.4.15 (bell, phone & Emergency lighting) | x | 1.5 emergency light needs battery | 6/19/2020 | |
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | 8.6.4.9 car top and inside of elevator need cleaned | |||
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | Note starter contacts need replaced for pump motor | |||
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | 8.6.1.6.5 fire extinguisher hasn't been checked since 2016 | |||
MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | needs current certificate posted in machine room | |||
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - Car Emergency Systems - 8.6.4.15 (bell, phone & Emergency lighting) | x | emergency light in elevator does not work | 5/10/2021 | |
MO Minimum : Elevators | (H) - Machine Rooms | (H)4 | machine room floor and under pump unit needs to be cleaned and all non essential items removed | |||
MO Minimum : Elevators | (I) - Pits | (I)1 | drain in the pit drains out on a concrete area also any loss of oil from pit area | |||
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | x | Emergency/auxiliary lighting shall work with power loss. Repeat violation from 2020. | 6/10/2022 | |
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) | x | Emergency/auxiliary lighting shall work with power loss. Repeat violation from 2020. | 6/14/2022 | |
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | 0 Compliant/Required Documentation & MCP shall be kept in equipment room(neat/organized) including Wiring Diagrams, Oil log &Fire service log, recorded monthly. (Provided by Elev Co.) | 4/20/2023 | ||
MO Minimum : Elevators | (I) - Pits | (I)1 | Clean Pit | 4/20/2023 | ||
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.5.5.2 Oil Leakage Collection | Oil Collection bucket shall be in the elevator pit, not outside of pit | 4/20/2023 |