Inspection
Inspection Details
Equipment ID
14345
14345
Inspection Date
6/28/2018
6/28/2018
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Kurt Zimmerman
Kurt Zimmerman
Mechanic Name
John Hambrough
John Hambrough
Relief Valve Pressure
Slide
Governor Rope Pull
Door Closing Force
External ID
f9395679-09a0-42b4-9f77-d0c8d187edea
f9395679-09a0-42b4-9f77-d0c8d187edea
Location
Plaza Frontenac
97 PLAZA FRONTENAC ST, FRONTENAC, MO
97 PLAZA FRONTENAC ST, FRONTENAC, MO
Owner
Plaza Frontenac
97 PLAZA FRONTENAC ST, FRONTENAC, MO 63131-3510
97 PLAZA FRONTENAC ST, FRONTENAC, MO 63131-3510
Billing
Attn: Plaza Frontenac
97 PLAZA FRONTENAC ST, FRONTENAC, MO 63131-3510
97 PLAZA FRONTENAC ST, FRONTENAC, MO 63131-3510
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | (T)2 | No | No | 7.3 Right Handrail has multiple cracks. Repair/Replace Handrail. | 10/2/2018 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | (T)2(E) | No | No | Replace broken comb plate. Lower landing. | 9/22/2020 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Testing incomplete. Test upper & lower comb impact devices. Re-inspection required | 5/11/2023 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.11.6.2(i) Step Demarcation | Yes | No | Replace broken step demarcation strip on escalator step tread. Re-inspection required | 5/11/2023 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.8.4 Escalator Combplates | Yes | No | Comb-step impact devices shall be tested to verify the requirement of 6.1.6.3.13. | 6/1/2023 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.8.3 Step/Skirt Performance Index | Yes | No | The step/skirt performance index testing required by 8.6.8.15.19 must be performed and witnessed. | 6/1/2023 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.11.5.2(i) Demarcation lighting | Yes | No | The demarcation lights shall be illuminated when running in automatic operation. | 6/1/2023 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | (T)2(B) | No | No | Start switches shall automatically return to the center position when released. The bottom start switch is not meeting this requirement. | 7/6/2023 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | (T)2 | No | No | The procedure specified by 8.6.11.6.2 shall be utilized when starting an escalator. | 7/6/2023 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.1.4 Maintenance Records | No | No | A record of authorized personnel trained as specified in 8.6.11.6.2 shall be kept on the premises where the escalator(s) or moving walk(s) or both is located and shall be available to the authority having jurisdiction. Provide list of trained and authorized personnel to inspection company. | 7/6/2023 |
| Missouri Minimum : Escalators | (T) - Existing Dumbwaiters, Escalators and Moving Walks | 8.6.8.1 Escalator Handrails | Yes | No | The handrail speed monitoring device, when provided, shall cause electric power to be removed from the driving-machine motor & brake when the speed of either handrail deviates from the step speed by 15% or more & continuously within a 2 - 6 second range. The right handrail speed sensor is not working and shall be reapired. | 8/25/2025 |