Inspection
Inspection Details
Equipment ID
10337
10337
Inspection Date
6/10/2021
6/10/2021
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Tim Crafton
Tim Crafton
Mechanic Name
Jeff Setchfield
Jeff Setchfield
Relief Valve Pressure
380
380
Slide
Governor Rope Pull
Door Closing Force
24
24
External ID
fd41adff-d076-4582-8fa6-b5c8ab22decc
fd41adff-d076-4582-8fa6-b5c8ab22decc
Location
Candlewood Suites
485 S Mount Auburn Rd, Cape Girardeau, MO
Phone: (573) 334-6868
485 S Mount Auburn Rd, Cape Girardeau, MO
Phone: (573) 334-6868
Owner
ARV Group, LLC
827 VALLEY CREEK DR, FARMINGTON, MO 63640-1970
827 VALLEY CREEK DR, FARMINGTON, MO 63640-1970
Billing
Attn: ARV GROUP LLC
827 VALLEY CREEK DR, FARMINGTON, MO 63640-1970
827 VALLEY CREEK DR, FARMINGTON, MO 63640-1970
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | conversion - reinspect | Yes | No | Replace phase one key switch. Tumbler assembly wore out, allowing any key to activate - re-inspect. | 7/15/2019 |
| conversion | conversion | conversion - reinspect | Yes | No | Repair inoperative emergency phone - re-inspect. | 7/15/2019 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.5 - Car lighting and receptacles | 8.6.4.15 Emergency Lighting | Yes | No | EMG LIGHT UNIT NOT WORKING, BATTERY GOOD. RE-INSPECTION REQUIRED. | 6/10/2021 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | No | No | GENERAL MAINTENANCE REQUIREMENTS: WRITTEN MCP, WRITTEN TEST PROCEDURES FOR CAT 1 TEST & OVERSPEED VALVE TEST; MCP SHALL BE ON JOB | 6/10/2021 |
| A17.1-2016 : Elevators | 5.15.2 Unsealed Overspeed Valve | 8.6.5.16.5 (Re-Inspect) | Yes | No | A17.1 - 8.6.5.16.5 OVER SPEED VALVE NOT SEALED. PERFORM REQUIRED 5 YR OSV TESTING WITHIN 90 DAYS, PER MISSOURI DEPARTMENT OF FIRE SAFETY/ ELEVATOR SAFETY DIVISION BY 9/10/2021 | 6/8/2022 |
| A17.1-2016 : Elevators | 5.15.2 Unsealed Overspeed Valve | 8.6.5.16.5 (Re-Inspect) | Yes | No | A17.1 - 8.6.5.16.5 OVER SPEED VALVE NOT SEALED ( PERFORM REQUIRED 5 YR OSV TESTING WITHIN 30 DAYS, PER MISSOURI DEPARTMENT OF FIRE SAFETY/ ELEVATOR SAFETY DIVISION BY. SECOND CITING OF UNSEALED OSV (6/10/21). | 7/22/2022 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.5 - Car lighting and receptacles | 8.6.4.15 Emergency Lighting | Yes | No | A17.1 2004 Elevators 1.5 - Car lighting and receptacles 8.6.4.15 Emergency Lighting. CAR EMGENCY LIGHTING SHALL WORK. (OTIS) RE-INSPECTION RQD | 7/22/2024 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.5 - Housekeeping | 8.6.4.8 Machine Rooms and Machinery Spaces | No | No | A17.1 2004 8.6.4.8.2 Equipment in Machine Rooms 8.6.4.8.2 Articles or materials not necessary for the maintenance or operation of the elevator shall not be stored in machine rooms and machinery spaces. (OWNER) | 8/14/2024 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.5 - Housekeeping | 8.6.4.8 Machine Rooms and Machinery Spaces | No | No | A17.1 2004 8.6.4.8.2 Equipment in Machine Rooms 8.6.4.8.2 Articles or materials not necessary for the maintenance or operation of the elevator shall not be stored in machine rooms and machinery spaces. (OWNER) (OWNER SIGN OFF ON VIOLATION REMOVED) THIRD OFFENSE | 1/29/2025 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | 11 CSR 40-5.100 State Operating Certificate and Local Operating Certificate (2) Display of State Operating Certificate. The owner, operator, lessee or agent of either shall post the operating certificate in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. For installations without an elevator room the state operating certificate shall be posted as directed by the chief elevator inspector. | 8/14/2024 |