Inspection
Inspection Details
Equipment ID
23051
23051
Inspection Date
6/25/2018
6/25/2018
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Kurt Zimmerman
Kurt Zimmerman
Mechanic Name
John Hambrough
John Hambrough
Relief Valve Pressure
Slide
Governor Rope Pull
n/a
n/a
Door Closing Force
22
22
External ID
c7c74370-41c9-4dac-923b-a0ab87b86eaa
c7c74370-41c9-4dac-923b-a0ab87b86eaa
Location
Lindell Residences LLC
4653 LINDELL BLVD, SAINT LOUIS, MO
4653 LINDELL BLVD, SAINT LOUIS, MO
Owner
Lindell Residences LLC
4653 LINDELL BLVD, SAINT LOUIS, MO 63108-3701
4653 LINDELL BLVD, SAINT LOUIS, MO 63108-3701
Billing
Attn: Lindell Residences LLC
4653 LINDELL BLVD, SAINT LOUIS, MO 63108-3701
4653 LINDELL BLVD, SAINT LOUIS, MO 63108-3701
Violations
Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
---|---|---|---|---|---|---|
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.12 - Pipes, wiring, and ducts | 8.11.2.1.3(r) | open electric boxes. | 5/24/2023 | ||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 3.14 - Hoistway clearances | 8.11.2.1.3(t) | landing head hitting final limit switch | 5/24/2023 | ||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.13 - Governor,overspeed switch and seal | 8.11.2.1.2(bb) | x | test tag on governor missing. | 1/9/2019 | |
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - n/a | n/a | Clean elevator pit. | 5/24/2023 | ||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.6 - Car emergency signal | 8.11.2.1.1(f) (Insp code) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | x | Emergency phone does not work. | 2/4/2021 | |
A17.1-2016 : Elevators | 1.17 - Standby power operation | 8.6.4.19.7 (Re-Inspection) | x | Emergency evacuation system needs battery replaced. Re-inspection required | 3/6/2023 | |
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | A copy of the current state operating certificate shall be on display in the machine room | 3/20/2023 | ||
A17.1-2016 : Elevators | 1.6 - Car emergency signal | 8.6.4.15 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | x | Emergency phone is not operable, needs repaired. Re-inspection required | 4/4/2025 | |
MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | A copy of the current state operating certificate shall be displayed in the machine room | |||
A17.1-2016 : Elevators | 1.17 - Standby power operation | 8.6.4.19.7 (Re-Inspection) | x | Need to test elevator on emergency generator power operation. Re-inspection required | 4/4/2025 | |
A17.1-2016 : Elevators | 2.14 - Code data plate | 8.9 | Need to install code data plate with required information | |||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.17 - Standby power operation | 2.27.2 | x | Emergency Power shall be tested. |