Inspection
Inspection Details
Equipment ID
798
798
Inspection Date
8/9/2017
8/9/2017
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Unknown Conversion
Unknown Conversion
Mechanic Name
Relief Valve Pressure
260
260
Slide
Governor Rope Pull
Door Closing Force
15
15
External ID
Location
Expedia Terminal
5000 W Kearney, Suite 15, Springfield, MO
Phone: (417) 868-0500
5000 W Kearney, Suite 15, Springfield, MO
Phone: (417) 868-0500
Owner
Spgf. Branson Nat. Airport
2300 N. Airport Blvd., Springfield, MO 65802
2300 N. Airport Blvd., Springfield, MO 65802
Billing
Attn: Spgf. Branson Nat. Airport
2300 N Airport Blvd Ste 100, , MO 65802
2300 N Airport Blvd Ste 100, , MO 65802
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | need current certificate posted in machine room in frame | 11/8/2018 |
| conversion | conversion | n/a | No | No | need a set of electrical prints for elevator | 11/8/2018 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | 40-5.100--there is no current certificate posted | 4/19/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.1.6.3 Controllers ,Wiring and Wiring Diagrams | No | No | needs a set of wiring diagrams | 4/19/2021 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | needs curerent certificate posted | 4/19/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.1.6.3 Controllers ,Wiring and Wiring Diagrams | No | No | No wiring diagrams | 4/19/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | No | No | Mount fire extinguisher on wall | 4/19/2021 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)8 | No | No | A 12X12 junction box located in machine room above pump unit has no cover exposing power wiring to elevator controller | 4/19/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.5.5.2 Oil Leakage Collection | No | No | Clean excess oil from pump units drip pan | 4/19/2021 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post updated certificate | 4/19/2021 |
| A17.1-2016 : Elevators | 1.6 - Car emergency signal | 8.6.4.15 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Must Make Emergency Phone operable. 8.6.4.15 | 3/17/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6 General Maintenance Methods | No | No | Must make Car top Stop Switch operable. | 10/14/2025 |