Inspection
Inspection Details
Equipment ID
5009
5009
Inspection Date
6/18/2018
6/18/2018
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Edward Balsat
Edward Balsat
Mechanic Name
Keith Tynes, Jr
Keith Tynes, Jr
Relief Valve Pressure
Slide
Governor Rope Pull
N/A
N/A
Door Closing Force
18
18
External ID
55905329-c426-4b9b-8c3a-2edeb090eab2
55905329-c426-4b9b-8c3a-2edeb090eab2
Location
Euclid Plaza Bldg
625 N EUCLID AVE, SAINT LOUIS, MO
625 N EUCLID AVE, SAINT LOUIS, MO
Owner
Cullinan Euclid, LLC
7707 N KNOXVILLE AVE, PEORIA, IL 61614-2080
7707 N KNOXVILLE AVE, PEORIA, IL 61614-2080
Billing
Attn: 625 Lofts Euclid
625 N EUCLID AVE, SAINT LOUIS, MO 63108-1690
625 N EUCLID AVE, SAINT LOUIS, MO 63108-1690
Violations
Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
---|---|---|---|---|---|---|
MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | A17.1 - 2004 - 1.6 - Could not establish 2-way communication. - Reinspection Required | 10/9/2018 | ||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.6 - Ventilation | 2.7.5.2 | The machine room temperature shall be kept within the manufacturers recommended range. | 1/13/2022 | ||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 1/13/2022 | ||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.17 - Standby power operation | 8.11.2.1.1(q) | x | Emergency power shall be tested. | 7/31/2020 | |
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 11 CSR 40-5.090 Inspection and Testing | 8.11 Periodic Inspection and Test. | x | The firefighters phase 1 key-switch and jewel located in the fire command room shall be operational. Fire service has been tested and works properly, however this fire service command panel does not operate as intended. The fire service command panel shall be operational. | 10/16/2020 | |
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.17 - Standby power operation | 8.11.2.1.1(q) | x | Emergency power shall be tested. Building personnel were unsuccessful in transferring main elevator power over to generator power. | 10/16/2020 | |
MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | x | The firefighters phase 1 key-switch and jewel located in the fire command room shall be operational. Fire service has been tested and works properly, however this fire service command panel does not operate as intended. The fire service command panel shall be operational. | 5/4/2022 | |
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.6 - Car emergency signal | 8.11.2.1.1(f) (Insp code) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | x | The emergency phone is not being answered. A two-way communications means shall be provided. | 9/27/2022 | |
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. | 6/1/2022 | ||
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.5 - Car lighting and receptacles | 8.6.4.15 Emergency Lighting | x | The in car emergency light shall be operational. | 9/27/2022 | |
ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 1.17 - Standby power operation | 2.27.2 | x | Elevators that are equipped to operate on emergency power shall be tested with no load in the car while operating on the emergency generator. | 12/15/2023 | |
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | x | The in car emergency telephone shall be operational. | 12/15/2023 | |
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | x | The in car emergency telephone shall be operational. | 5/1/2024 | |
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | x | The elevator ADA telephone inside the elevator is not operating correctly. Check and repair the programming of this phone for proper operation and passenger safety. Reinspection is required. This issue has been ongoing since 2022, if this is not resolved in 14 days the elevator shall be removed from service and a red tag issued until resolved. | ||
MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) | x | The emergency light fixture inside the elevator is not operational and shall be repaired. Reinspection required. | ||
MO Minimum : Elevators | (N) - Guide Rails | (N)1 | x | The counterweight guide rails in the pit have been severely damaged by corrosion and shall be repaired and anti corrosion coating appplied to the car and counterweight guide rails as well. Reinspection required to ensure proper repairs are completed. |