Inspection
Inspection Details
Equipment ID
19758
19758
Inspection Date
7/9/2021
7/9/2021
Inspection Type
Other Inspection
Other Inspection
Inspector Name
Steven Salabay
Steven Salabay
Mechanic Name
John Ryan
John Ryan
Relief Valve Pressure
NA
NA
Slide
Governor Rope Pull
Door Closing Force
External ID
772cc34f-8bcd-45fc-aa41-d2ed0b23d41c
772cc34f-8bcd-45fc-aa41-d2ed0b23d41c
Location
Ungerboeck Systems
100 Ungerboeck Park, Dardenne Prairie, MO
Phone: (636) 300-5606
100 Ungerboeck Park, Dardenne Prairie, MO
Phone: (636) 300-5606
Owner
Attn: Dan Padgett
Ungerboeck Systems International
100 Ungerboeck Park, Dardenne Prairie, MO 63368
Phone: (636) 300-5606 Ext: 172
Email: dan.padgett@ungerboeck.com
Ungerboeck Systems International
100 Ungerboeck Park, Dardenne Prairie, MO 63368
Phone: (636) 300-5606 Ext: 172
Email: dan.padgett@ungerboeck.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) | Yes | No | Rep[air phone in car | 7/27/2021 |
| MO Minimum : Elevators | (S) - Fire Service | 8.6.11.1 Monthly Test and Log | No | No | Perform monthly fire service testing and document on log in machine room | 8/7/2026 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current state certificate in machine room | 8/7/2026 |
| MO Minimum : Elevators | (S) - Fire Service | 8.6.11.1 Monthly Test and Log | No | No | Perform monthly fire service and document on log in machine room | 8/7/2026 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 2.27.7 Firefighters' Emergency Operation: Operating Procedures | No | No | Install phase 1 fire service instructions at 1st floor switch | 8/7/2026 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Remove water from pit | 8/7/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | No | No | Provide current year tested fire extinguisher in the elevator machine room. | 8/7/2026 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current State Elevator Certificate. | 8/7/2026 |
| A17.1-2016 : Elevators | 5.15.2 Unsealed Overspeed Valve | 8.6.5.16.5 (Re-Inspect) | Yes | No | OSV is due for testing. | 8/14/2024 |
| A17.1-2016 : Elevators | 2.40 - Maintenance Records | 8.6.1.2.2 On-Site Documentation | No | No | Provide updated MCP. | 8/7/2026 |
| A17.1-2016 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current State Elevator Certificate. | 8/7/2026 |
| A17.1-2016 : Elevators | 1.3 - Operating control devices | 8.6.3.7 | No | No | Door open button missing, provide. | 8/7/2026 |
| A17.1-2016 : Elevators | 5.11 - Plunger and Cylinder | 8.6.5.5 | No | No | Cylinder packing is worn and leaking, repair as needed. | 8/7/2026 |
| A17.1-2016 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 8.6.4.7 Cleaning of Pits | No | No | Remove oil from sump hole. | 8/7/2026 |
| A17.1-2016 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 8.6.4.7 Cleaning of Pits | No | No | Determine if the sump pump works, if not replace. Replace sump hole cover when completed. | 8/7/2026 |
| A17.1-2016 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 8.6.4.7 Cleaning of Pits | No | No | Clean the pit (oil). | 8/7/2026 |