Inspection
Inspection Details
Equipment ID
18506
18506
Inspection Date
6/29/2021
6/29/2021
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Curtis Belew
Curtis Belew
Mechanic Name
Charles Sheriff
Charles Sheriff
Relief Valve Pressure
Slide
NA
NA
Governor Rope Pull
NA
NA
Door Closing Force
NA
NA
External ID
a3b85bfe-aab9-43f4-886e-d808cc6a5d32
a3b85bfe-aab9-43f4-886e-d808cc6a5d32
Location
Walnut Street Station
151 E Front St, Washington, MO
Phone: (636) 390-1030
151 E Front St, Washington, MO
Phone: (636) 390-1030
Owner
Attn: City of Washington
City of Washington
410 Lafwayette St, Washington, MO 63090
Phone: (636) 390-1071
City of Washington
410 Lafwayette St, Washington, MO 63090
Phone: (636) 390-1071
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| A17.1-1996 : Elevators | 5.8 - Car safeties and guiding members - including roped-hydraulic elevators installed under A17.1b-1989 and later editions | 1001.2(e)10 | Yes | No | Unit is tagged as having a category 5 full load safety test in 2018, but there is no proof of that test happening. Verification of the Category 5 full load safety test is required. If verification is not found, a Category 5 test is required. | 6/29/2020 |
| A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted on or near the equipment in a noncombustible frame with a clear protective vision plate over it. | 2/5/2026 |
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | Yes | The in car alarm bell shall be operational on auxiliary power. Note: Elevator Red Tagged due to no working emergency communication device. | 7/21/2021 |
| A17.1-1996 : Elevators | 2.14 - Code data plate | 1200.6 | No | No | A code data plate shall be provided on the controller. | 2/5/2026 |
| A17.1-1996 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | No | No | A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022) | 2/5/2026 |
| A17.1-1996 : Elevators | 3.16 - Traveling cables and junction boxes | 1001.2(c)(22) | No | No | The traveling cable must be run in raceway to the controller. Note: Currently, the T-cable leaves the hoistway, and runs to the controller without being enclosed. | 2/5/2026 |
| A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted near the lift. | 11/3/2022 |
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 211.1(a)(3) Battery Backup Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Four hour battery back up required for emergency alarm or two-way communication. The two way communication device shall be operational on regular power and on battery power. | 11/3/2022 |
| A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | The state operating certificate is expired. | 2/5/2026 |
| A17.1-1996 : Elevators | 2.7 - Fire Extinguisher | 1206.1h | No | No | The fire extinguisher is expired. | 2/5/2026 |