Inspection
Inspection Details
Equipment ID
962
962
Inspection Date
7/2/2018
7/2/2018
Inspection Type
Reinspection
Reinspection
Inspector Name
Derek Rankin
Derek Rankin
Mechanic Name
Relief Valve Pressure
Slide
NA
NA
Governor Rope Pull
NA
NA
Door Closing Force
NA
NA
External ID
5239dfe9-a59b-4cba-a435-f8a550352059
5239dfe9-a59b-4cba-a435-f8a550352059
Location
Parkview Place
701 WESTGATE AVE, UNIVERSITY CITY, MO
701 WESTGATE AVE, UNIVERSITY CITY, MO
Owner
Parkview Housing Corp
701 WESTGATE AVE, UNIVERSITY CITY, MO 63130-3509
701 WESTGATE AVE, UNIVERSITY CITY, MO 63130-3509
Billing
Attn: Parkview Tower Apts
701 WESTGATE AVE, UNIVERSITY CITY, MO 63130-3509
701 WESTGATE AVE, UNIVERSITY CITY, MO 63130-3509
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency phone is not being answered. | 9/30/2020 |
| A17.1-1996 : Elevators | 1.12 - Car enclosure | 204 | No | No | Replace missing cab panel. | 12/13/2021 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Annual inspection incomplete. Need to test fire service. | 4/5/2021 |
| A17.1-1996 : Elevators | 5.9 - Buffers and emergency terminal speed limiting devices | 201 | Yes | No | Counterweight buffer needs to be repaired. | 4/5/2021 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Phone in elevator cab does not work. Phone line problem. | 11/29/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.2.1 Repair Parts | No | No | Top right counterweight roller has a worn out bearing, replace roller. | 4/27/2026 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | No | No | Elevator machine room lighting is inadequate, provide at least 19 foot candles of lighting in all areas of machine room | 4/27/2026 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)4 | No | No | Remove all non-elevator equipment stored in elevator machine room. | 4/27/2026 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)8 Car Lighting | No | No | The ceiling has been removed and there shall be plastic tubes covering the fluorescent bulbs | |
| A17.1-1996 : Elevators | 1.18 - Restricted opening of car or hoistway doors | 111.5 Restricted Opening of Hall/Car Doors | Yes | No | The car door restrictor shall be made operational. Re-inspection required | |
| A17.1-2016 : Elevators | 3.17 - Door and gate equipment | 2.11 | No | No | The sill closer at the first floor shall be made operational |