Inspection
Inspection Details
Equipment ID
8778
8778
Inspection Date
7/10/2018
7/10/2018
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Dennis Parker
Dennis Parker
Mechanic Name
Scott Breihan
Scott Breihan
Relief Valve Pressure
580
580
Slide
Governor Rope Pull
Door Closing Force
27
27
External ID
c7c6b327-38a8-474f-8906-22a1a6b67519
c7c6b327-38a8-474f-8906-22a1a6b67519
Location
Shrewsbury Community Center
5200 SHREWSBURY AVE, SAINT LOUIS, MO
5200 SHREWSBURY AVE, SAINT LOUIS, MO
Owner
Shrewsbury Community Center
5200 SHREWSBURY AVE, SAINT LOUIS, MO 63119-4349
5200 SHREWSBURY AVE, SAINT LOUIS, MO 63119-4349
Billing
Attn: Shrewsbury Community Center
5200 SHREWSBURY AVE, SAINT LOUIS, MO 63119-4349
5200 SHREWSBURY AVE, SAINT LOUIS, MO 63119-4349
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | Emergency lights shall work | 9/4/2018 |
| conversion | conversion | n/a | No | No | Seal rupture valve | 9/4/2018 |
| A17.1-1996 : Elevators | 1.5 - Car lighting and receptacles | 204.7 | No | No | Emergency light not working. | 9/4/2018 |
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Alarm bell not working. | 11/27/2019 |
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Repair inoperative emergency phone. | 9/9/2020 |
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Phone rings to police. Reprogram phone and reinspect. | 9/29/2021 |
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency alarm bell does not work. | 9/29/2021 |
| A17.1-1996 : Elevators | 3.17 - Door and gate equipment | 1001.2(c)(23) | No | No | Bottom floor hoistway door pick-up roller assembly has one roller, requires two. | 9/22/2022 |
| A17.1-1996 : Elevators | 5.11 Plunger and Cylinder | 1206.5b(4) | No | No | Cylinder packing is worn and leaking. | 9/22/2022 |
| A17.1-1996 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current operating certificate in machine room. | 9/22/2022 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | 8.6.5.16.5 Over Speed Valve Testing | No | No | Valve not sealed | 9/22/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) | No | No | Provide MCP | 9/22/2022 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Expired | 9/22/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.2.1 Repair Parts | No | No | The position indicating or “PI” device in the car was not operational on the day of inspection. Repair “PI” device to indicate the position of the elevator car. | 12/5/2023 |