Inspection
Inspection Details
Equipment ID
25606
25606
Inspection Date
7/15/2021
7/15/2021
Inspection Type
Alteration
Alteration
Inspector Name
Michial Linenfelser
Michial Linenfelser
Mechanic Name
Marcus Geno
Marcus Geno
Relief Valve Pressure
420
420
Slide
Governor Rope Pull
Door Closing Force
Na
Na
External ID
b53b8a65-0c77-460a-bd83-5ad6719cbd82
b53b8a65-0c77-460a-bd83-5ad6719cbd82
Location
314 Building
314 N Jefferson Ave, St. Louis, MO
Phone: (314) 621-3440
314 N Jefferson Ave, St. Louis, MO
Phone: (314) 621-3440
Owner
Attn: Hudson Company
Hudson Company
PO Box 220425, St. Louis, MO 63122
Phone: (000) 000-0000
Hudson Company
PO Box 220425, St. Louis, MO 63122
Phone: (000) 000-0000
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (A) - Hoistways | (A)12 | No | No | Hoistways containing freight elevators shall be fully enclosed. There were two access doors noted on the rear wall of the hoistway (Top of floor 2 and top of floor 3), along with an access door in the ceiling of the hoistway that accesses the roof. All access doors shall be permanently closed (mechanically fastened or welded shut) to eliminate access to the hoistway. | 1/25/2022 |
| MO Minimum : Elevators | (C) - Car Enclosure: Freight | (C)5 | No | No | The light bulb inside the freight enclosure shall be guarded to prevent breakage. | 1/25/2022 |
| MO Minimum : Elevators | (F) - Electrical Switches | (F)9 | No | No | The existing shorting bars in the mainline elevator disconnect shall be replaced with fuses properly sized for the application. | 1/25/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) | No | No | A written Maintenance Control Program shall be in place to maintain the equipment in compliance with the requirements of Section 8.6, along with the required on-site documentation and maintenance records provided. | 1/25/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.5 Code Data Plate | No | No | A code data plate shall be provided and securely attached to the main line disconnect or controller stipulating this elevator to be inspected to Missouri Minimums. | 1/25/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.2.1 Repair Parts | No | No | The elevator did have a run/stop switch located on the top of the car. However, it had been broken off. A new run/stop switch shall be provided. | 1/25/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | No | No | A Class “ABC” fire extinguisher shall be provided in the elevator machine room, convenient to the access door. | 1/25/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - Door Systems 8.6.4.13 (Re-Inspection) | Yes | No | The front car gate was too loose between the guides and running uneven. This gate shall have the door guides and relating cables adjusted for smooth and secure door operation. | 1/25/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.2.1 Repair Parts | No | No | There was a junction box above the traveling cable that was not completely secured to the wall. This box shall be secured to prevent future damage to the elevator electrical components. | 1/25/2022 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | The elevator machine and control equipment shall be located in a separate room or separated space. Other mechanical equipment can be located in the room but must be separated by a 6-foot fence with a self-closing and self-locking gate, operable from the interior space without use of a key. Pipes conveying liquid, gas, or vapor that cross overhead of elevator equipment shall be guarded or guttered. | 1/25/2022 |
| MO Minimum : Elevators | (O) - Existing Hydraulic Elevators | (O)2 | No | No | The pressure relief valve on the hydraulic power unit was set too high. The unit is slated for immediate replacement and the new hydraulic pump shall conform to this section. The new relief valve shall be preset to open at a pressure not greater than that necessary to maintain one hundred twenty-five percent (125%) of working pressure. | 1/25/2022 |