Inspection
Inspection Details
Equipment ID
13869
13869
Inspection Date
8/10/2021
8/10/2021
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Kurt Zimmerman
Kurt Zimmerman
Mechanic Name
James DeBell
James DeBell
Relief Valve Pressure
570
570
Slide
Governor Rope Pull
Door Closing Force
22 / 25
22 / 25
External ID
5a296290-abd2-413d-ae12-66f1b73ca99b
5a296290-abd2-413d-ae12-66f1b73ca99b
Location
Hollywood Casino St. Louis
777 Casino Center Dr, Maryland Heights, MO
Phone: (314) 770-8278
777 Casino Center Dr, Maryland Heights, MO
Phone: (314) 770-8278
Owner
Attn: John Koshinski
Hollywood Casino St. Louis
777 Casino Center Dr, Maryland Heights, MO 63043
Phone: (314) 770-8278
Email: John.Koshinski@pngaming.com
Hollywood Casino St. Louis
777 Casino Center Dr, Maryland Heights, MO 63043
Phone: (314) 770-8278
Email: John.Koshinski@pngaming.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | No current MO state operating certificate in the elevator machine room. | |
| conversion | conversion | conversion - reinspect | Yes | No | Alarm bell does not work | 8/9/2018 |
| conversion | conversion | conversion - reinspect | Yes | No | Rear car door restrictor does not work | 8/9/2018 |
| conversion | conversion | conversion - reinspect | Yes | No | Emergency lights do not work | 8/9/2018 |
| conversion | conversion | conversion - reinspect | Yes | No | Gap between lower hoistway door and jam is over 3/8 has 1inch gap | 8/9/2018 |
| conversion | conversion | conversion - reinspect | Yes | No | replace rusted conduit in machine room | 8/9/2018 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency phone shall work with power off. | 5/16/2019 |
| MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | No | No | Pit light shall work. | |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)3 | No | No | Repair or replace cartop exit switch. | |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Need battery for emergency phone. | 9/9/2020 |
| MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | No | No | Repair pit light. | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.5.5.1 Examination and Maintenance | No | No | Remove corrosion from supply pipe that leads from machine room to pit. | |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)8 | No | No | Cover exposed wiring, due to corrosion, in machine room. | |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | 8.6.5.16.5 Over Speed Valve Testing | No | No | OSV is not sealed needs a full load test. Perform load test and check tripping speeds within 90 days or less. (11-10-21) REINSPECT | |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Elevator pit is full of water. Remove water and debris | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | Alarm bell in elevator cab does not work. Repair | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | Enclose exposed electrical wiring on car top door reopening control box |