Inspection
Inspection Details
Equipment ID
801
801
Inspection Date
8/18/2021
8/18/2021
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Wayne Ingram
Wayne Ingram
Mechanic Name
Kevin Crossland
Kevin Crossland
Relief Valve Pressure
420
420
Slide
Governor Rope Pull
Door Closing Force
8
8
External ID
a0c3e18e-6ff6-46a6-a28c-e2436d89162c
a0c3e18e-6ff6-46a6-a28c-e2436d89162c
Location
Expedia Terminal
5000 W KEARNEY ST STE 15, SPRINGFIELD, MO
Phone: (417) 868-0500
5000 W KEARNEY ST STE 15, SPRINGFIELD, MO
Phone: (417) 868-0500
Owner
Attn: John Copelin
Spgf. Branson Nat. Airport
2300 N Airport Blvd, Springfield, MO 65802
Phone: (000) 000-0000
Email: JCopelin@flyspringfield.com
Spgf. Branson Nat. Airport
2300 N Airport Blvd, Springfield, MO 65802
Phone: (000) 000-0000
Email: JCopelin@flyspringfield.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | needs smoke detector at first floor, heat detector in machine room needs to be smoke detector all need tested when replaced | 11/8/2018 |
| conversion | conversion | n/a | No | No | air conditioner not cooling in machine room needs replaced or repaired | 11/8/2018 |
| conversion | conversion | n/a | No | No | no current certificate posted | 11/8/2018 |
| conversion | conversion | n/a | No | No | water in pit sump not working | 11/8/2018 |
| conversion | conversion | conversion - reinspect | Yes | No | Telephone line dead--REINSPECT REQUIRED | 7/11/2018 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | I-1 water in pit sump not working 40-5.100 needs current certificate posted in machine room | 4/30/2021 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | needs current certificate posted | 4/30/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - Car Emergency Systems - 8.6.4.15 (bell, phone & Emergency lighting) | Yes | No | 1.5 energency light needsa battery | 9/30/2020 |
| MO Minimum : Elevators | (S) - Fire Service | (S)1 | Yes | No | needs smoke detector first and secomd floor landings and the heat detector in the machine room needs to be a smoke detector | 9/30/2020 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | the pit needs to be dry and clean | 4/30/2021 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | Unauthorized material | 4/30/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.5.5.2 Oil Leakage Collection | No | No | Remove oil scavenger pump | 4/30/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.3.1 Replacement Parts | No | No | car riding lantern missing cover/lamps | 4/30/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency Light/Bell failed | 5/10/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.1.6.3 Controllers ,Wiring and Wiring Diagrams | No | No | No wiring diagrams | 4/30/2021 |
| A17.1-2016 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 8.6.4.7 Cleaning of Pits | No | No | Pit must be free of water. (currently 2" standing water in pit) | 10/16/2024 |