Inspection
Inspection Details
Equipment ID
17058
17058
Inspection Date
9/10/2021
9/10/2021
Inspection Type
Reinspection
Reinspection
Inspector Name
Wayne Ingram
Wayne Ingram
Mechanic Name
Kevin Crossland
Kevin Crossland
Relief Valve Pressure
NA
NA
Slide
Governor Rope Pull
Door Closing Force
NA
NA
External ID
2577576c-29ad-4f2e-87cd-ac9ff2e8a80f
2577576c-29ad-4f2e-87cd-ac9ff2e8a80f
Location
Still Waters Condo
21 Stillwater Trl, Branson, MO
Phone: (417) 338-2323
21 Stillwater Trl, Branson, MO
Phone: (417) 338-2323
Owner
Attn: Scott Battaglia
Still Waters Condo
21 Stillwater Trl, Branson, MO 65616
Phone: (417) 338-2323
Alt Phone: (417) 338-8422 Ext: 109
Email: scottab@stillwatersresort.com
Still Waters Condo
21 Stillwater Trl, Branson, MO 65616
Phone: (417) 338-2323
Alt Phone: (417) 338-8422 Ext: 109
Email: scottab@stillwatersresort.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 1004.2(a)(6) (Hydro) Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Phone Failed | 5/29/2020 |
| A17.1-1996 : Elevators | 2.6 - Ventilation | 1001.2(b)(6) | No | No | AC unit not cooling | 7/18/2019 |
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 211.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Phone failed | 8/11/2020 |
| A17.1-2016 : Elevators | 1.15 - sign and operating device symbols | 8.6.1.6.7 | No | No | No DO not use elevator in case of fire signs posted | 9/15/2021 |
| A17.1-2016 : Elevators | 2.3 - Lighting and receptacles | 8.11.3.1.2(f) | No | No | Replace lamp in machine room light fixture | 9/15/2021 |
| A17.1-2016 : Elevators | 2.8 - Pipes, wiring, and ducts | 8.11.3.1.2(k) | No | No | Replace cover on duct junction box located in machine room | 9/15/2021 |
| A17.1-2016 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 8.11.3.1.5(a) | No | No | Pit light out | 9/15/2021 |
| A17.1-1996 : Elevators | 1.5 - Car lighting and receptacles | 204.7a (3)(a) Standby Illumination in the car. (Re-Inspection) | Yes | No | Emergency Light gone replacement | 7/12/2023 |
| A17.1-1996 : Elevators | 1.5 - Car lighting and receptacles | 204.7a (3)(a) Standby Illumination in the car. (Re-Inspection) | Yes | No | Must Mske Emergency Light operable. 8.6.4.15 | 7/7/2025 |
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 211.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Must make emergency Phone operable. 8.6.4.15 | 7/7/2025 |
| A17.1-1996 : Elevators | 2.7 - Fire Extinguisher | 1206.1h | No | No | Must provide current test tag on Mach room Fire Extinguisher. | 7/12/2025 |
| A17.1-1996 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 1206.2a (Pits and Hoistways) | No | No | Pit must be kept Free of Water. ( currently 2" standing water). | 7/12/2025 |