Inspection
Inspection Details
Equipment ID
25560
25560
Inspection Date
9/2/2021
9/2/2021
Inspection Type
New Installation
New Installation
Inspector Name
Edward Balsat
Edward Balsat
Mechanic Name
Benjamin Postawko
Benjamin Postawko
Relief Valve Pressure
Slide
Instantaneous
Instantaneous
Governor Rope Pull
25/112
25/112
Door Closing Force
17F/17R
17F/17R
External ID
6c6ab4c9-3725-4bef-add7-2db86b10aaa0
6c6ab4c9-3725-4bef-add7-2db86b10aaa0
Location
Hudson Apartments
5655 Pershing Ave, St. Louis, MO
Phone: (000) 000-0000
5655 Pershing Ave, St. Louis, MO
Phone: (000) 000-0000
Owner
Attn: Kilamanjaro V, LLC
Kilamanjaro V, LLC
PO Box 28514, St. Louis, MO 63146
Phone: (000) 000-0000
Kilamanjaro V, LLC
PO Box 28514, St. Louis, MO 63146
Phone: (000) 000-0000
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| A17.1-2016 : Elevators | 3.10 - Hoistway construction | 8.7.2.1.1 Hoistway Enclosure Walls | Yes | No | Patch the holes in the hoistway. | 9/3/2021 |
| A17.1-2016 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 8.10.2.2.5(a) | Yes | No | Make the pit sump pump operational. | 9/3/2021 |
| A17.1-2016 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 2.2.2.6 Sump Pump Covers | Yes | No | Pit sump shall have a cover installed. | 9/3/2021 |
| A17.1-2016 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 8.6.4.7 Cleaning of Pits | Yes | No | The pit shall be cleaned. | 9/3/2021 |
| A17.1-2016 : Elevators | 1.4 - Sills and car floor | 8.10.2.2.1(d) | Yes | No | The floor outside the elevator entrance at the bottom landing shall be ramped to the hoistway sill. | 9/3/2021 |
| A17.1-2016 : Elevators | 1.4 - Sills and car floor | 8.10.2.2.1(d) | Yes | No | Cab flooring shall be installed. | 9/3/2021 |
| A17.1-2016 : Elevators | 2.7 - Fire Extinguisher | 8.10.2.2.2(l) | Yes | No | Fire extinguisher shall be mounted near controller. | 9/3/2021 |
| A17.1-2016 : Elevators | 1.6 - Car emergency signal | 2.27.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency phone line not working | 1/2/2024 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)8 Car Lighting | No | No | Car ceiling light is missing, replace. | 10/4/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.4.9 Cleaning of Top of Cars | No | No | Clean the car top. | 10/4/2024 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Clean the pit. | 10/4/2024 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)4 | No | No | Car door gap ( when closed is excessive) adjust as needed. | 10/4/2024 |
| A17.1-2016 : Elevators | 2.7 - Fire Extinguisher | 8.6.1.6.5 | No | No | Provide current year tested fire extinguisher in (near) elevator mechanical space. | 10/4/2024 |