Inspection
Inspection Details
Equipment ID
23639
23639
Inspection Date
8/17/2021
8/17/2021
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Gary Beadle
Gary Beadle
Mechanic Name
Walter Tauchert
Walter Tauchert
Relief Valve Pressure
610
610
Slide
Governor Rope Pull
Door Closing Force
F18/r18
F18/r18
External ID
49f55f07-10c5-4da8-8968-d50880c7dc35
49f55f07-10c5-4da8-8968-d50880c7dc35
Location
Nazareth Living Center
2 NAZARETH LN, SAINT LOUIS, MO
Phone: (314) 487-3950
2 NAZARETH LN, SAINT LOUIS, MO
Phone: (314) 487-3950
Owner
Attn: Nazareth Living Center
Nazareth Living Center
2 NAZARETH LN, SAINT LOUIS, MO 63129
Phone: (000) 000-0000
Nazareth Living Center
2 NAZARETH LN, SAINT LOUIS, MO 63129
Phone: (000) 000-0000
Billing
Attn: Nazareth Living Center
Nazareth Living Center
2 NAZARETH LN, SAINT LOUIS, MO 63129
Phone: (000) 000-0000
Email: thomas.matzenbacher@benedictineliving.org
Nazareth Living Center
2 NAZARETH LN, SAINT LOUIS, MO 63129
Phone: (000) 000-0000
Email: thomas.matzenbacher@benedictineliving.org
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.8 - Pipes, wiring, and ducts | 2.8.2 (Re-Inspection) | No | No | A heat detector device has been installed in the elevator hoistway and shall be removed. The heat detector device is designed to disconnect power to the elevator before a sprinkler head activation in a vital elevator controlled space. There is no sprinkler head to activate at the top of the hoistway. | 10/9/2018 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | No | No | Provide on-site maintenance records. | 10/6/2022 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 8.6.4.7 Cleaning of Pits | No | No | Clean pit. | 10/6/2022 |
| A17.1-2016 : Elevators | 2.40 - Maintenance Records | 8.6.1.2.1(a) | No | No | Provide MCP | 10/6/2022 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 8.6.4.7 Cleaning of Pits | No | No | Clean pit | 10/6/2022 |
| A17.1-2016 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post certificate | 10/6/2022 |
| A17.1-2016 : Elevators | 5.15 - Overspeed Valve | 8.6.5.16.5 | No | No | OSV is due for full load test and have tripping speed checked. Re-inspection required | 11/21/2023 |
| A17.1-2016 : Elevators | 1.6 - Car emergency signal | 2.27.1 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency phone in elevator cab does not work, needs repair. Re-inspection required | 11/21/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) | Yes | No | Emergency light does not work. Re-inspection required | 11/21/2023 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency alarm in car does not work. Re-inspection required | 11/21/2023 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | 8.6.5.16.5 Over Speed Valve Testing (Re-Inspect) | Yes | No | OSV is due for full load test and have tripping speed checked. Re-inspection required | 11/21/2023 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | 8.6.5.16.5 Over Speed Valve Testing (Re-Inspect) | Yes | No | OSV is due for full load test and have tripping speed checked. Re-inspection required | 4/3/2024 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Elevator appears to have emergency generator backup power, which needs to be scheduled & tested & witnessed by an elevator inspector to complete inspection. Re-inspection required | 7/8/2025 |