Inspection
Inspection Details
Equipment ID
10700
10700
Inspection Date
6/27/2018
6/27/2018
Inspection Type
Alteration
Alteration
Inspector Name
John Ryan
John Ryan
Mechanic Name
Gerard Hussey
Gerard Hussey
Relief Valve Pressure
Slide
NA
NA
Governor Rope Pull
NA
NA
Door Closing Force
NA
NA
External ID
19be5046-57ce-4c85-bfb8-16a23c8d1bf6
19be5046-57ce-4c85-bfb8-16a23c8d1bf6
Location
Parkview Elderly Apts
4451 FOREST PARK AVE, SAINT LOUIS, MO
4451 FOREST PARK AVE, SAINT LOUIS, MO
Owner
The Habitat Company
4451 FOREST PARK AVE, SAINT LOUIS, MO 63108-2243
4451 FOREST PARK AVE, SAINT LOUIS, MO 63108-2243
Billing
Attn: The Habitat Company
4451 FOREST PARK AVE, SAINT LOUIS, MO 63108-2243
4451 FOREST PARK AVE, SAINT LOUIS, MO 63108-2243
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | Pits shall be clean | 5/9/2019 |
| conversion | conversion | n/a | No | No | Emergency phone not working | 5/9/2019 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)8 Car Lighting | No | No | Cab lighting needs to be guarded. | 5/9/2019 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)12 (Door open zones) | Yes | No | Car door restrictor does not work. | 5/7/2020 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Clean elevator pit. | 7/21/2020 |
| MO Minimum : Elevators | (L) - Wire Ropes-Hoisting, Governor and Tiller | (L)12 (Re- Inspection) | Yes | No | Suspension ropes are below minimum diamter. | 5/12/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.2.1 General Maintenance Requirements Documentation | No | No | Written maintenance control program shall be kept on site for each elevator. | 6/15/2021 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | All pits shall be kept dry & clean and free of equipment or material not relating to the operation of the elevator | 3/26/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) | No | No | A MCP shall be provided for each unit and kept on site | 3/26/2024 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Elevator was not running at scheduled test date. Repair elevator and perform annual no load test of elevator. | 1/5/2024 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Emergency generator test needs to be witnessed when all Modernizations are completed. | 5/27/2025 |
| A17.1-2016 : Elevators | 3.12 - Pipes, wiring, and ducts | 2.8 | Yes | No | After the third car modernization is finished, all covers on electrical boxes shall be installed. | 5/27/2025 |
| A17.1-2016 : Elevators | 2.8 - Pipes, wiring, and ducts | 2.8 | Yes | No | All cross wiring connections shall be complete. | 5/27/2025 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | Elevator cab must have a permanent slip resistant floor installed. | |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)1 | No | No | Machine room door must be self-closing and self-locking | |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Emergency power must be tested annually. |