Inspection
Inspection Details
Equipment ID
14815
14815
Inspection Date
10/1/2021
10/1/2021
Inspection Type
Reinspection
Reinspection
Inspector Name
Christopher "RED" Staton
Christopher "RED" Staton
Mechanic Name
Relief Valve Pressure
na
na
Slide
Governor Rope Pull
Door Closing Force
na
na
External ID
720bdee9-7e60-4fcf-a1c6-4213d5f1e41d
720bdee9-7e60-4fcf-a1c6-4213d5f1e41d
Location
Burrell Children's Center
1300 E Bradford Pkwy, Springfield, MO
Phone: (417) 269-5400
Email: rod.lippold@burrellcenter.com
1300 E Bradford Pkwy, Springfield, MO
Phone: (417) 269-5400
Email: rod.lippold@burrellcenter.com
Owner
Attn: Burrell Health Center
Burrell Health Center
1300 E Bradford Pkwy, Springfield, MO 65804
Phone: (417) 761-5081
Email: Rod.Lippold@burrellcenter.com
Burrell Health Center
1300 E Bradford Pkwy, Springfield, MO 65804
Phone: (417) 761-5081
Email: Rod.Lippold@burrellcenter.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| A17.1-1996 : Elevators | 2.5 - Housekeeping | 1206.2b (Clean Machine Room) | No | No | non elevator items stored in machine room | 10/10/2018 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency/auxiliary lighting shall work with power loss. | 2/26/2021 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | 2-way communication device shall call 24/7 number | 2/26/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | No | No | MCP shall be kept in equipment room, including Oil loss log and Fire service testing log, recorded monthly. No MCP or Logs currently. | 2/26/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency/auxiliary lighting shall work with power loss. | 2/26/2021 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | 2-way communication device shall call 24/7 number | 2/26/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | No | No | MCP shall be kept in equipment room, including Oil loss log and Fire service testing log, recorded monthly. No MCP or Logs currently. | 2/26/2021 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | 2-way communication device shall work and give proper location. (Busy signal, repeatedly) REINSPECTION REQUIRED | 10/1/2021 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | 2-way communication device shall work and give proper location. (Busy signal, repeatedly) REINSPECTION REQUIRED | 10/1/2021 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | 2-way communication device shall work and give proper location (REINSPECTION 14days to REDTAG) | 8/31/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | No | No | Compliant/Required Documentation & MCP shall be kept in equipment room(neat/organized) including Wiring Diagrams, Oil log &Fire service log, recorded monthly. (Provided by Elevator Serv Co.) | 2/13/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.4.9 Cleaning of Top of Cars | No | No | Clean Cartop | 2/13/2023 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Clean pit. | 2/13/2023 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | 2-way communication device shall work and give proper location (REINSPECTION 14days to REDTAG) | 8/31/2022 |