Inspection
Inspection Details
Equipment ID
8795
8795
Inspection Date
9/28/2021
9/28/2021
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Edward Balsat
Edward Balsat
Mechanic Name
Dustin Arnett
Dustin Arnett
Relief Valve Pressure
320
320
Slide
Governor Rope Pull
Door Closing Force
28
28
External ID
1a841476-bdd0-457b-907e-16dc9e3492c8
1a841476-bdd0-457b-907e-16dc9e3492c8
Location
Lindell Building
4236 Lindell Blvd, St. Louis, MO
Phone: (314) 361-1984
4236 Lindell Blvd, St. Louis, MO
Phone: (314) 361-1984
Owner
Attn: Helix Realty, Inc.
Helix Realty, Inc.
1020 Union Blvd, Ste 120, St. Louis, MO 63113
Phone: (314) 367-7646
Email: helixrealty@gmail.com
Helix Realty, Inc.
1020 Union Blvd, Ste 120, St. Louis, MO 63113
Phone: (314) 367-7646
Email: helixrealty@gmail.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | conversion - reinspect | Yes | No | "Call Cancel" Doesn't work. Phase II fire service | 1/7/2019 |
| conversion | conversion | n/a | No | No | Oil in pit - Clean pit | 3/9/2023 |
| MO Minimum : Elevators | (A) - Hoistways | (A)17 | No | No | The exposed pipes in the hoistway shall be removed or enclosed in a manner to separate them from the hoistway. This violation was previous noted and customer may need to apply for variance. | 10/1/2020 |
| MO Minimum : Elevators | (A) - Hoistways | (A)16 | No | No | Verify the voltage of wiring in the hoistway. Wiring shall comply with NEC and may need to be enclosed in conduit once voltage is determined. | 10/1/2020 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | No | No | A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022) | 7/18/2022 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO state operating certificate shall be displayed in the elevator machine room. | 7/18/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.5.5.2 Oil Leakage Collection | No | No | A written record shall be kept of the quantity of hydraulic fluid added to the system and emptied from leakage collection containers and pans, shall not exceed 5 gal before removal, shall be covered, and shall not be permitted to overflow. Note: Per the State of Missouri AHJ: "The use of oil recovery systems to return the hydraulic fluid back into the main reservoir by automatic means or by gravity feed prevents proper monitoring of the gland packing and seals", and "machine rooms cannot be used as containment areas". | 7/18/2022 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | The pit shall be kept dry. | 7/18/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.13 - Door systems | Yes | No | Car door electric eye shall be operational. | 2/27/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.5.5.1 Examination and Maintenance | No | No | Correct source of hydraulic oil leak at packing. | 7/18/2022 |
| MO Minimum : Elevators | (A) - Hoistways | (A)17 | No | No | Pipes conveying liquids are not allowed in the hoistway. | 7/18/2022 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post a current MO State operating certificate in the machine room. | 9/20/2023 |
| MO Minimum : Elevators | (A) - Hoistways | (A)17 | Yes | No | The exposed pipes in the hoistway shall be removed or enclosed in a manner to separate them from the hoistway. This violation has been cited several times. Re-Inspection Required. | 12/18/2023 |
| MO Minimum : Elevators | (A) - Hoistways | (A)16 | Yes | No | Wiring in hoistway not enclosed in conduit. There is also a 4x4 box missing a cover. The violation regarding the wiring has been cited several times. Re-Inspection required. | 12/18/2023 |
| MO Minimum : Elevators | (S) - Fire Service | 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) | Yes | No | Initiating fire reall cancels car calls, but car runs to top floor before recalling to 1st landing. Car does not currently stop at next available floor. Take corrective action and re-test fire service. | 12/18/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.3.1 Replacement Parts | No | No | Pressure fitting on muffler in machine room is tripping hazard/safety hazard. Replace/relocate or enclose. | 9/20/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | The 2-way communication device shall give proper location message, including full address, city, and state. | 12/18/2023 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)3 | No | No | The top emergency exit shall be secured. | 9/20/2023 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)8 | No | No | The 2x4 and 4x4 electrical boxes in the machine room needs to be properly secured to wall, have wiring inside box and cover installed. | 9/20/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.5.5.1 Examination and Maintenance | No | No | Verify and provide the pressure rating on the pit shut off valve to the inspection company. If valve is under-rated, take corrective action as needed. | 9/20/2023 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 10/9/2024 |