Inspection
Inspection Details
Equipment ID
17187
17187
Inspection Date
9/22/2021
9/22/2021
Inspection Type
5 Year Annual Inspection
5 Year Annual Inspection
Inspector Name
James Mueller
James Mueller
Mechanic Name
Bill Suedkamp
Bill Suedkamp
Relief Valve Pressure
Slide
9.5"
9.5"
Governor Rope Pull
100/860
100/860
Door Closing Force
22
22
External ID
2a8e58ef-96f4-4eeb-8ae7-1b56c2ecbb6b
2a8e58ef-96f4-4eeb-8ae7-1b56c2ecbb6b
Location
Senate Apartments
265 Union Blvd, St. Louis, MO
Phone: (314) 367-7900
265 Union Blvd, St. Louis, MO
Phone: (314) 367-7900
Owner
Attn: Larry McFadden
275 on the Park
275 UNION BLVD, St. Louis, MO 63108
Phone: (000) 000-0000
275 on the Park
275 UNION BLVD, St. Louis, MO 63108
Phone: (000) 000-0000
Billing
Attn: Larry McFadden
275 on the Park - Annex
275 UNION BLVD, St. Louis, MO 63108
Phone: (000) 000-0000
275 on the Park - Annex
275 UNION BLVD, St. Louis, MO 63108
Phone: (000) 000-0000
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | conversion - reinspect | Yes | No | Cover hole in hoistway at basement level. | 10/18/2018 |
| conversion | conversion | n/a | No | No | Replace missing cab light bulb and properly guard lights. | |
| conversion | conversion | n/a | No | No | There shall be a light in the pit. | |
| conversion | conversion | conversion - reinspect | Yes | No | Car door restrictor shall work. | 10/18/2018 |
| conversion | conversion | conversion - reinspect | Yes | No | In cab emergency telephone shall work. | 10/18/2018 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | Provide code compliant machine room door handle and lock. | |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)8 Car Lighting | No | No | Replace the missing cab light bulb and properly guard lights. | |
| MO Minimum : Elevators | (A) - Hoistways | (A)13 | No | No | Repair the hole in the hoistway at the basement level. | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | No | No | An ABC type fire extinguisher shall be kept in the machine room. | |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Display the current state operating certificate. | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6 General Maintenance Methods | No | No | Repair the hole in the hoistway at the basement. | |
| MO Minimum : Elevators | (S) - Fire Service | (S)1 | Yes | Yes | Door reopening devices that are sensitive to smoke shall be rendered inoperative on Firemans' Return service. | 9/22/2021 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | All pipes conveying liquid, vapor, or gas that are above or near any elevator equipment shall be guarded or guttered. | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6 General Maintenance Methods | No | No | A tool to reset the car safeties shall be available on-site. | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.13.1(l) Means to restrict hoistway/car door opening (Door Restrictors) (Re-Inspection) | Yes | No | The car door restrictor shall be operational. | 7/5/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1- 8.6.4.15 Car Emergency Systems (Emergency Light) (Re-Inspection) | Yes | No | The in car emergency telephone shall be operational. | 7/5/2022 |
| MO Minimum : Elevators | (S) - Fire Service | 8.11.2.2.6 Firefighters’ Emergency Operation (Re-Inspection) | Yes | No | The electronic safety edge is not bypassed on Phase 1 fire recall. Take corrective action. | 7/5/2022 |
| MO Minimum : Elevators | (I) - Pits | (I)6 (Pit Lighting) | No | No | The pit lighting shall be operational. | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | No | No | A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022) | |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)2 | No | No | Condensation dripping on duct work. All pipes conveying liquid, vapor, or gas that are above or come near elevator equipment shall be guarded or guttered. | |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (1) Minimum Standard | Yes | No | Could not test windup safeties. A tool to reset the car safeties shall be available on-site. | 2/14/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.7 Signs and Data Plates | No | No | 110V disconnect shall be labeled. Where there is more than one machine in a room, the disconnect for each machine shall be conspicuously numbered to correspond to the machine it controls. | |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | The test is incomplete. Fire service, testing of light/alarm/phone with 110V source removed, inspection of pit, inspection of door restrictor, and inspection of hoistway need to be completed. | 2/14/2023 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - 8.6.4.15 Car Emg Sys (Phone or alarm not functioning Mandatory Re-Inspection due in 14 days) | Yes | No | The in car emergency telephone shall be operational. | 4/2/2024 |
| MO Minimum : Elevators | (L) - Wire Ropes-Hoisting, Governor and Tiller | (L)12 (Re- Inspection) | Yes | No | Rope used as a connection from the safety to the governor rope, including rope wound on the safety-rope drum, shall be made of metal, and shall be corrosion resistant (currently iron/steel). Replace and retest for soft set and pullout length. | 4/17/2024 |
| A17.1-2016 : Elevators | 2.3 - Lighting and receptacles | 2.8.2 | Yes | No | 2.3.1 - Machine room lighting needs to be repaired. One or more bulbs is not working. | 4/17/2024 |
| A17.1-2016 : Elevators | 4.2 - Hoistway doors | 8.6.4.13 Door Systems | Yes | No | Replace missing secondary fire tab on top of 12th floor hoistway door. | 4/17/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.7 Signs and Data Plates | Yes | No | Replace faded "Do not use elevator in case of fire" signage as needed. | 4/17/2024 |
| A17.1-2016 : Elevators | 2.6 - Ventilation | 2.7.9.2 | Yes | No | Machine room climate control is non-functional. | 10/8/2024 |
| A17.1-2016 : Elevators | 1.6 - Car emergency signal | 8.6.4.15 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Two-way communication device shall work. Button lights up, but does not dial (communication loss works). | |
| A17.1-2016 : Elevators | 1.18 - Restricted opening of car or hoistway doors | 8.6.4.13.1(l)(Door Restrictor) | Yes | No | Car door restrictor shall work at all floors. | |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. |