Inspection
Inspection Details
Equipment ID
7902
7902
Inspection Date
11/18/2021
11/18/2021
Inspection Type
5 Year Annual Inspection
5 Year Annual Inspection
Inspector Name
Robert Kehm
Robert Kehm
Mechanic Name
David Howerton
David Howerton
Relief Valve Pressure
Slide
TBD
TBD
Governor Rope Pull
TBD
TBD
Door Closing Force
22F/22R
22F/22R
External ID
8db19d58-ff57-47e1-9ab2-67d745d466be
8db19d58-ff57-47e1-9ab2-67d745d466be
Location
Siro OP Royal Oak, LLC
4960 Laclede Ave, St. Louis, MO
Phone: (000) 000-0000
4960 Laclede Ave, St. Louis, MO
Phone: (000) 000-0000
Owner
Attn: Royals Oak
Siro OP Royal Oak, LLC
4960 Laclede Ave, St. Louis, MO 63108
Phone: (000) 000-0000
Email: Richard.Woolard@reachltc.com
Siro OP Royal Oak, LLC
4960 Laclede Ave, St. Louis, MO 63108
Phone: (000) 000-0000
Email: Richard.Woolard@reachltc.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| A17.1-1996 : Elevators | 2.1 - Access to machine space | 1001.2(b)(1) | The machine room door shall be self-closing and self-locking. | 5/12/2023 | ||
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | x | There shall be an emergency telephone located in the elevator car. | 7/3/2019 | |
| A17.1-1996 : Elevators | 3.12 - Pipes, wiring, and ducts | 1001.2(c)(18) | Install covers on electrical boxes in the hoistway. | 5/12/2023 | ||
| A17.1-1996 : Elevators | 2.1 - Access to machine space | 1001.2(b)(1) | The machine room door shall be self-locking and self-closing. (Repeat Violation) | 5/12/2023 | ||
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | x | An in car emergency telephone is required. (Repeat violation) | 10/13/2020 | |
| A17.1-1996 : Elevators | 3.12 - Pipes, wiring, and ducts | 1001.2(c)(18) | Install covers on electrical boxes in hoistway. (Repeat Violation) | 5/12/2023 | ||
| A17.1-1996 : Elevators | 3.8 - Top emergency exit | 1001.2(c)(12) | Properly secure car top exit. | 5/12/2023 | ||
| A17.1-1996 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 106.1e Illumination of Pits | The pit shall be kept dry. | 5/12/2023 | ||
| A17.1-1996 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 106.1e Illumination of Pits | The pit shall be kept clean and dry. | 5/12/2023 | ||
| A17.1-1996 : Elevators | 3.2 - Car top light and outlet | 1001.2(c)(2) | The car top lighting shall be operational. | 5/12/2023 | ||
| A17.1-1996 : Elevators | 2.3 - Housekeeping | n/a | Clean the car top. | 5/12/2023 | ||
| A17.1-1996 : Elevators | 2.5 - Housekeeping | 1206.2b (Clean Machine Room) | The machine room shall be cleaned. | 5/12/2023 | ||
| A17.1-1996 : Elevators | 2.1 - Access to machine space | 1001.2(b)(1) | The machine room door shall be self-locking and self-closing. | |||
| A17.1-1996 : Elevators | 1.6 - Car emergency signal | 1001.2(a)(6) (Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | x | An in car emergency telephone is required. | 11/18/2021 | |
| A17.1-1996 : Elevators | 3.12 - Pipes, wiring, and ducts | 1001.2(c)(18) | Install covers on electrical boxes in hoistway. | |||
| A17.1-1996 : Elevators | 1.13 - Emergency exit | 1001.2(a)(13) | Properly secure car top exit. | |||
| A17.1-1996 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. Evacuation procedures are missing. (This item is for notification purposes for future violation in 2022) | 10/17/2023 | ||
| A17.1-1996 : Elevators | 2.17 - Drive machine brake | 1001.2(b)(15) | x | x | The pads on the rope gripper are worn down below tolerance. | 11/23/2021 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | x | The test is incomplete. The following testing items remain: pull out/pull thru of governor, governor switch and jaw, governor full load test of car safeties, buffer and counterweight buffer test. | 11/23/2021 | |
| A17.1-1996 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. Evacuation procedures are missing. | |||
| A17.1-2016 : Elevators | 2.17 - Drive machine brake | 8.6.4.19.11 Ascending Overspeed Protection, Unintended Movement Devices, and Emg Brake | x | The pads on the rope gripper are worn down below tolerance. | 3/28/2023 | |
| A17.1-1996 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. | |||
| A17.1-2016 : Elevators | 2.17 - Drive machine brake | 8.6.4.19.11 Ascending Overspeed Protection, Unintended Movement Devices, and Emg Brake | x | x | Pads on rope gripper are worn down below tolerance. (2nd Notice) | 6/1/2023 |
| A17.1-1996 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 106.1 | Pit has an excessive amount of water in it. Water shall be removed from the pit and the pit shall be kept clean and dry. | |||
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 - Door Systems 8.6.4.13 (Re-Inspection) | x | x | The relating of car and hoistway doors is not operating properly. Take corrective action as needed. | 6/1/2023 |
| A17.1-1996 : Elevators | 1.7 - Car door or gate | 204.4 | x | x | Car interlocking devices not operating properly. Car runs with the doors open. Elevator has been red tagged until repairs are made. | 6/1/2023 |