Inspection
Inspection Details
Equipment ID
23444
23444
Inspection Date
11/30/2021
11/30/2021
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Wayne Ingram
Wayne Ingram
Mechanic Name
Paul Bartlett
Paul Bartlett
Relief Valve Pressure
Slide
Stopped Level
Stopped Level
Governor Rope Pull
NA / NA
NA / NA
Door Closing Force
24
24
External ID
5298ebad-ed85-41eb-91a4-295fc03c46fe
5298ebad-ed85-41eb-91a4-295fc03c46fe
Location
Bear Village Phase 5
943 S KIMBROUGH AVE, SPRINGFIELD, MO
Phone: (417) 864-6303
943 S KIMBROUGH AVE, SPRINGFIELD, MO
Phone: (417) 864-6303
Owner
Attn: Bryan Properties
Bryan Properties
519 E Walnut, Springfield, MO 65806
Phone: (417) 864-6303
Email: alexis@bryan-properties.net
Bryan Properties
519 E Walnut, Springfield, MO 65806
Phone: (417) 864-6303
Email: alexis@bryan-properties.net
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| A17.1-2016 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post updated certificate | 12/7/2020 |
| A17.1-2016 : Elevators | 2.5 - Housekeeping | 8.6.4.8 Machine Room and Machinery Space | No | No | Unauthorized Material in machine room | 12/7/2020 |
| A17.1-2016 : Elevators | 2.40 - Maintenance Records | 8.6.1.2.1(a) | No | No | Maintenance records required | 12/7/2020 |
| A17.1-2016 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post certificate | 2/1/2022 |
| A17.1-2016 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 8.6.11.1 Firefighters’ Emergency Operation Documentation | No | No | Required to be checked monthly | 2/1/2022 |
| A17.1-2016 : Elevators | 1.6 - Car emergency signal | 8.6.4.15 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Phone Failed | 12/7/2022 |
| A17.1-2016 : Elevators | 2.40 - Maintenance Records | 8.6.1.2.2 On-Site Documentation | No | No | No records | 2/1/2022 |
| ASME A17.1 2004 with 2005 Addendum and 2005 : Elevators | 2.41 - Maintenance Records | 8.6.1.4 | No | No | No Records | 9/18/2024 |
| A17.1-2016 : Elevators | 1.6 - Car emergency signal | 8.6.4.15 Phone or alarm not functioning (Mandatory Re-Inspection due in 14 days) | Yes | No | Phone Failed | 9/13/2023 |
| A17.1-2016 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 8.6.11.1 Firefighters’ Emergency Operation Documentation | No | No | Fireman's Recall system is to be checked monthly | 9/18/2024 |
| A17.1-2016 : Elevators | 2.4 - Machine space | 8.6.4.8 Machine Room and Machinery Space | No | No | Unauthorize material | 9/18/2024 |
| A17.1-2016 : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post updated one | 9/18/2024 |
| A17.1-2016 : Elevators | 6.4 - Firefighters' service (A17.1b-1989 and later editions) | 8.6.11.1 Firefighters’ Emergency Operation Documentation | No | No | Fireman's recall is to be checked monthly. | 9/18/2024 |