Inspection
Inspection Details
Equipment ID
19788
19788
Inspection Date
11/18/2021
11/18/2021
Inspection Type
Major Alteration
Major Alteration
Inspector Name
Vincent Daus
Vincent Daus
Mechanic Name
Kyle Prosser
Kyle Prosser
Relief Valve Pressure
Slide
14"
14"
Governor Rope Pull
130/330
130/330
Door Closing Force
23
23
External ID
6898c13d-3253-491d-b5bd-72d7f6ec8984
6898c13d-3253-491d-b5bd-72d7f6ec8984
Location
Hawkeye Hotels
1019 Pine St, St. Louis, MO
Phone: (314) 436-2355
1019 Pine St, St. Louis, MO
Phone: (314) 436-2355
Owner
Attn: Hawkeye Hotels
Hawkeye Hotels
2706 James Street, Coralville, IA 52241
Phone: (319) 752-7400 Ext: 1037
Email: ap4@hawkeyehotels.com
Hawkeye Hotels
2706 James Street, Coralville, IA 52241
Phone: (319) 752-7400 Ext: 1037
Email: ap4@hawkeyehotels.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| A17.1-2016 : Elevators | 2.40 - Maintenance Records | 8.6.1.2.2 On-Site Documentation | Yes | No | A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022) | 7/17/2023 |
| A17.1-2016 : Elevators | 2.40 - Maintenance Records | 8.6.1.2.2(b)(1) | Yes | No | Need procedures for inspections and tests not described in A17.2. | 7/17/2023 |
| A17.1-2016 : Elevators | 2.40 - Maintenance Records | 8.6.1.2.2(d)(1) | Yes | No | Written evacuation procedures for elevators by authorized persons and emergency personnel shall be available on-site. | 7/17/2023 |
| A17.1-2016 : Elevators | 3.12 - Pipes, wiring, and ducts | 8.10.2.2.3(r) | Yes | No | There is coax and other cables running the length of the hoistway shall be removed from the hoistway. Only pipes, wiring, and ducts used in connection with the elevator may be installed in the hoistway, remove the cables. | 7/17/2023 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | Yes | No | A state ID sticker shall be posted on the elevator controller. | 7/17/2023 |
| A17.1-2016 : Elevators | 5.1 - Pit access, lighting, stop switch, and condition | 8.6.4.7 Cleaning of Pits | No | No | The pit shall be kept clean. Remove excess debris. | 3/11/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | No | No | Machine room shall have proper fire extinguisher and shall have current monthly/annual test tag. | 4/28/2026 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Current State operating certificate must be displayed in the machine room. | 4/28/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) | No | No | A code compliant MCP with related on-site documentation shall be located in the machine room. | 4/28/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.11.1 Firefighters' Emergency Operation & Documentation | No | No | Fire service testing must be documented monthly. | 4/28/2026 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Emergency power operation shall be tested. | 4/28/2026 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | No | No | Machine room shall have proper fire extinguisher and shall have current monthly/annual test tag. | |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Current State operating certificate must be displayed in the machine room. | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) | No | No | A code compliant MCP with related on-site documentation shall be located in the machine room. | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.11.1 Firefighters' Emergency Operation & Documentation | No | No | Fire service testing must be documented monthly. |