Inspection
Inspection Details
Equipment ID
6761
6761
Inspection Date
12/2/2021
12/2/2021
Inspection Type
Reinspection
Reinspection
Inspector Name
Ronnie Ritch
Ronnie Ritch
Mechanic Name
Andrew Schmitz
Andrew Schmitz
Relief Valve Pressure
Slide
na
na
Governor Rope Pull
na
na
Door Closing Force
na
na
External ID
77c88f17-0da1-42a4-9959-ef47c8e0031d
77c88f17-0da1-42a4-9959-ef47c8e0031d
Location
Hutcheson Arms Apts
2107 S Grand Blvd, St. Louis, MO
Phone: (000) 000-0000
2107 S Grand Blvd, St. Louis, MO
Phone: (000) 000-0000
Owner
Attn: Revival STL Construction, LLC
Revival STL Construction, LLC
PO Box 46721, St. Louis, MO 63146
Phone: (314) 852-6755
Email: anshul@revivalstl.com
Revival STL Construction, LLC
PO Box 46721, St. Louis, MO 63146
Phone: (314) 852-6755
Email: anshul@revivalstl.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | Hoistway doors have broken/missing sill door latches | 12/29/2021 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)7 | No | No | Electric panel missing cover,replace | 12/29/2021 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)7 | No | No | GFCI receptacles hanging by wires,repair per NEC. | 12/29/2021 |
| MO Minimum : Elevators | (C) - Car Enclosure: Freight | (C)5 | No | Yes | Car light hanging by wires, repair as needed. | 12/2/2021 |
| MO Minimum : Elevators | (C) - Car Enclosure: Freight | (C)4 | No | No | Replace missing emergency exit panel | 12/29/2021 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | No | No | Provide guard on bulbs in machine room. | 12/29/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.2.1 General Maintenance Requirements Documentation | No | No | Provide MCP | 12/29/2021 |
| MO Minimum : Elevators | (C) - Car Enclosure: Freight | (C)5 | No | No | Provide guard on car light | 12/29/2021 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6 General Maintenance Methods | No | No | Provide working car top light | 12/29/2021 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | No | No | Provide guard on bulbs in machine room over machines | 12/29/2021 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)8 | No | No | GFCI receptacles hanging by wires, with no cover. Repair per NEC | 12/29/2021 |
| MO Minimum : Elevators | (F) - Electrical Switches | (F)5 | Yes | Yes | Hall door switch is not working. Red-tagged, Re-inspection required | 1/30/2023 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | No | No | Provide guard on bulbs in machine room over machines | |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)8 | No | No | GFCI receptacles hanging by wires, with no cover, repair per NEC | |
| MO Minimum : Elevators | (F) - Electrical Switches | (F)9 | No | No | Replace disconnect with one that is lockable. The one that is in there has been damaged intentionally and cannot be locked out of service anymore. | |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | Pit should be kept clean & dry, pit has 2 feet of water in it | |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | Post current State Elevator Certificate. | |
| MO Minimum : Elevators | (F) - Electrical Switches | (F)9 | Yes | No | Main line disconnect is damaged, unable to perform lock out/tag out. Repair/replace (per code) as needed. | 4/7/2025 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (3) Testing Procedures (Re-Inspect) | Yes | No | Testing incomplete. Unit was shut down upon arrival. The entire annual inspection needs to be completed. The violations cited this day were discovered in the machine room while mechanics worked to make unit operational. | |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)7 | No | No | Machine room shall have a duplex receptacle rated at not less than 15A. Currently the only receptacle is in a side room and fully loaded with AC & phone. | |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)8 | No | No | Machine room AC unit not installed to OEM requirements for electrical. Currently plugged into an extension cord, which is plugged into a power strip, which is plugged into an outlet in the side room. Additionally outlet shall have a cover installed. | |
| MO Minimum : Elevators | (F) - Electrical Switches | (F)9 | No | No | Machine room disconnect has 2 large hole/knockouts missing. | |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)8 | No | No | Controller "LB" missing cover. | |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)8 | No | No | Machine room circuit breaker box cover has broken hinges. Properly repair or replace box. | |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)9 | No | No | Controller does not have reverse phase protection. | |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | No | No | Machine room lighting shall have switch control, currently lighting switch was removed and motion activated lamps installed. Motion activated lights are not allowed. | |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.2.2(a) On-Site Documentation (Up-to-Date Wiring Diagrams) | No | No | Up-to-date wiring diagrams shall be provided and permanently kept in the machine room. There are no schematics on-site. |