Inspection
Inspection Details
Equipment ID
10703
10703
Inspection Date
11/24/2021
11/24/2021
Inspection Type
Annual Inspection
Annual Inspection
Inspector Name
Curtis Belew
Curtis Belew
Mechanic Name
David Howerton
David Howerton
Relief Valve Pressure
350
350
Slide
Governor Rope Pull
Door Closing Force
19
19
External ID
5e757f9a-34c5-4fa7-81c7-4992a1fbc7f2
5e757f9a-34c5-4fa7-81c7-4992a1fbc7f2
Location
Ashley Apts
4954 W Pine Blvd, St. Louis, MO
Phone: (314) 803-2024
4954 W Pine Blvd, St. Louis, MO
Phone: (314) 803-2024
Owner
Attn: Fresh- Warehousing Fulfillment
Fresh- Warehousing Fulfillment
4300 Church Rd, East St. Louis, IL 62207
Phone: (618) 482-8725
Email: APrealestate@fwresults.com
Fresh- Warehousing Fulfillment
4300 Church Rd, East St. Louis, IL 62207
Phone: (618) 482-8725
Email: APrealestate@fwresults.com
Billing
Same as Owner
Violations
| Code | Item | Section | Reinspection | Red Tag | Reason For Violation | Fixed Date |
|---|---|---|---|---|---|---|
| conversion | conversion | n/a | No | No | Car emergency lighting shall work. | 3/18/2019 |
| conversion | conversion | n/a | No | No | Car emergency telephone needs to be re-programmed to the new elevator contractor. | 3/18/2019 |
| MO Minimum : Elevators | (S) - Fire Service | (S)1 | Yes | No | Phase 1 lobby key switch shall work. | 3/18/2019 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | In car emergency phone shall work on battery power. | 3/18/2019 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | (G)1 Maintenance, Repair and Replacements | No | No | A smoke detector, alarm horn, and strobe shall be permanently anchored in the pit. Currently hanging in the pit creating a head clearance issue. | 3/18/2019 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | No | No | The machine room lighting shall be operational. | 2/7/2020 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | No | No | The machine room lighting shall be operational and shall provide a minimum of 10 foot candles at the floor level and in front of the controller. | 11/17/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6.5 Fire Extinguishers | No | No | The fire extinguisher in the machine room is expired. A current tested, ABC type fire extinguisher shall be provided in the machine room. | 11/17/2022 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)5 (Machine Room Lighting) | No | No | The machine room lights shall be operational. Note: Both machine room lights must work. | 11/17/2022 |
| MO Minimum : Elevators | 11 CSR 40-5.090 Inspection and Testing | (1) Minimum Standard | Yes | No | The auxiliary power lowering operation shall be functional. | 8/25/2022 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)7 | No | No | All machine room wiring shall be enclosed. Note: Box covers are missing and wiring is exposed. | 11/17/2022 |
| MO Minimum : Elevators | (I) - Pits | (I)1 | No | No | The trash can full of trash and the abandoned fire pull station located in the pit shall be removed. | 11/17/2022 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)4 | No | No | Water shall not be allowed to accumulate on the machine room floor. | 11/17/2022 |
| MO Minimum : Elevators | CSR 40-5.100 State Operating Certificate | 5.100(2) Display of Operating Certificate | No | No | A current MO State operating certificate shall be posted in the elevator equipment room, in a noncombustible frame with a clear protective vision plate over it. | 11/17/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4 Maintenance records | No | No | A code compliant MCP and all the on-site documentation required by A17.1 2016 - 8.6.1.2.2 and 8.6.1.4 shall be provided in the machine room. (This item is for notification purposes for future violation in 2022) | 11/17/2022 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.6 General Maintenance Methods | No | No | Recommendation: A pressure switch shall be provided in the line between the cylinder and the valve which shall be activated by the loss of positive pressure at the top of the cylinder. Note: This unit is governed by MO Minimums code, which does not specifically require a pressure switch. | 11/17/2022 |
| MO Minimum : Elevators | (H) - Machine Rooms | (H)4 | No | No | Machine room has excessive water in it. Water shall not be allowed to accumulate on the machine room floor. Correct source of leak. | 8/20/2024 |
| MO Minimum : Elevators | (G) - Maintenance, Repair and Replacements | 8.6.1.4.1(a) On-Site Maintenance Records (MCP Records) | No | No | A code compliant MCP and all the on-site documentation shall be provided in the machine room. | 12/9/2025 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Emergency phone shall be operational. Phone will not call out. | 3/5/2025 |
| MO Minimum : Elevators | (B) - Car Enclosure: Passenger | (B)11 Phone or alarm not functioning ( Mandatory Re-Inspection due in 14 days) | Yes | No | Two-way communication means between the car and a location staffed by authorized personnel shall be provided. | 2/3/2026 |